background image

Page 11

INSTALLER'S GUIDE

Section 8. Warranty

Base 

Limited W

arranty

Subject to the ter

ms and conditions of this limited w

arr

anty

, T

rane U

.S

., Inc.

 (“Compan

y’) e

xtends a limited w

arr

anty against man

uf

actur

-

ing def

ects f

or the product(s) identified in 

Tab

les 1,

 1A,

 1B

 attached hereto (“Products’) that are installed in a residential/m

ulti-f

amily applica

-

tion (personal, f

amily or household pur

poses) under nor

mal use and maintenance in the United States and Canada.

  

This limited warranty applies to Pr

oducts man

ufactured on or after A

ugust 1,

 2011.

In order to maximiz

e the a

vailab

le benefits under this limited w

arr

anty

, the Purchaser (as defined belo

w) should read it in its entirety

.  

All repairs of Product par

ts co

vered under this limited w

arr

anty m

ust be made with author

iz

ed ser

vice par

ts and b

y a licensed HV

A

C ser

vice 

pro

vider

.  Additionally

, commercial applications are treated diff

erently under this limited w

arr

anty as stated in 

Tab

les 1,

 1A,

 1B 

attached 

hereto

.  

For pur

poses of this limited w

arr

anty

, “commercial applications”

 shall mean an

y application other than f

or personal, f

amily

, or household use

.

TERM:

 

 The limited w

arr

anty per

iod f

or Products is as stated in 

Tab

les 1,

 1A,

 1B

 attached hereto

.  If the Purchaser proper

ly registers the 

Products

, the limited w

arr

anty per

iod shall be e

xtended as stated in 

Tab

les 1,

 1A,

 1B

 attached hereto

.  Regardless of registr

ation, the Com

-

mencement Date f

or a limited w

arr

anty per

iod shall be the date that the or

iginal installation is complete and all Product star

t-up procedures 

ha

ve been proper

ly completed and v

er

ified b

y an installer’

s in

voice

.  If the installation and star

t-up date cannot be v

er

ified b

y the installer’

in

voice

, the Commencement Date shall be sixty (60) da

ys after the f

actor

y man

uf

acture date which is v

er

ified b

y the Product ser

ial n

umber

.  

Where a Product is installed in a ne

wly constr

ucted home

, the Commencement Date is the date the Purchaser purchased the residence from 

the b

uilder

.  Proof of Product purchase

, installation, and/or closing date of the residence ma

y be required to confir

m the Commencement Date

.  

The installation of Product replacement par

ts under this limited w

arr

anty shall not e

xtend the or

iginal w

arr

anty per

iod.

  The w

arr

anty pe

-

riod f

or an

y Product par

t replaced under this limited w

arr

anty is the applicab

le w

arr

anty per

iod remaining under the or

iginal Product w

arr

anty

.  

WHO IS CO

VERED:

 

 This limited w

arr

anty is pro

vided only to the or

iginal o

wner and his or her spouse (“Purchaser’) of the residence 

where the Products are or

iginally installed.

   

This w

arr

anty is not tr

ansf

er

ab

le e

xcept according to ter

ms stated on the applicab

le w

ebsite 

identified belo

w under Registr

ation Requirements

.  Compan

y has the r

ight to request an

y and all proof of Product purchase or installation and/

or closing date of the residence

.

WHA

T COMP

ANY 

WILL DO:

 

Compan

y ma

y request proof of Product purchase and/or installation in order to pro

vide Product par

ts 

under this limited w

arr

anty

.  As Compan

y’

s only responsibility and Purchaser’

s only remedy under this limited w

arr

anty

, Compan

y will fur

nish a 

replacement par

t to the licensed HV

A

C ser

vice pro

vider

, without charge f

or the par

t only

, to replace an

y Product par

t that f

ails due to a man

u-

factur

ing def

ect under nor

mal use and maintenance

.  

The Purchaser m

ust pa

y f

or an

y and all shipping and handling charges and other costs 

of w

arr

anty ser

vice f

or the replacement par

t.  If a Product par

t is not a

vailab

le

, Compan

y will, at its option, pro

vide a free suitab

le substitute 

par

t or pro

vide a credit in the amount of the then f

actor

y selling pr

ice f

or a ne

w suitab

le substitute par

t to be used b

y the Purchaser to

w

ards 

the retail purchase pr

ice of a ne

w Compan

y product.

  An

y ne

w Product purchase shall be at Purchaser’

s sole cost and e

xpense including, b

ut 

not limited to

, all shipping, remo

val, and installation costs and e

xpenses

.  

REGISTRA

TION REQ

UIREMENTS:

 

 All Products m

ust be proper

ly registered online b

y the Purchaser within sixty (60) da

ys after the 

Commencement Date to receiv

 

       the registered limited w

arr

anty ter

ms

.  

To register online

, go to:

http://www

.tr

ane

.com/Residential/F

or-Owners/W

arr

anties  or 

http://www

.amer

icanstandardair

.com/ser

vicesuppor

t/pages/w

arr

anty

.aspx   

and clic

“Begin Online Registr

ation.

”  If a Purchaser does not register within this stated time per

iod, the base limited w

arr

anty ter

ms 

shall apply

.    

ELIGIBILITY REQ

UIREMENTS:

  The f

ollo

wing items are required in order f

or the Products to be co

vered under this limited w

arr

anty:

• 

The Products m

ust be in the same location where the

y w

ere or

iginally installed.

• 

The Products m

ust be proper

ly installed, oper

ated, and maintained b

y a licensed HV

A

C ser

vice pro

vider in accordance with the Prod

-

uct specifications or installation, oper

ation, and maintenance instr

uctions pro

vided b

y Compan

y with each Product.

  F

ailure to conf

or

to such specifications and/or instr

uctions shall v

oid this limited w

arr

anty

.  Compan

y ma

y request wr

itten documentation sho

wing the 

proper pre

ventativ

e maintenance

.

• 

All Product par

ts replaced b

y Compan

y under this limited w

arr

anty m

ust be giv

en to the ser

vicing pro

vider f

or retur

n to Compan

y.

• 

Air handlers

, air conditioners

, heat pumps

, cased or uncased coils and stand-alone fur

naces m

ust be par

t of an Air Conditioning, 

Heating, and Refr

iger

ation Institute r

ated and matched system or a specification in a Compan

y pro

vided b

ulletin or otherwise appro

ved 

in wr

iting b

y a Compan

y author

iz

ed representativ

e.

EXCLUSIONS:

 The f

ollo

wing are not co

vered b

y this limited w

arr

anty:

• 

Labor costs including, but not limited to, costs for diagnostic calls or the removal and reinstallation of Products and/or Prod

uct parts.

• 

Shipping and freight expenses required to ship Product replacement parts.

• 

Failures, defects, or damage (including, but not limited to, any loss of data or property) caused by (1) any third party produc

t, service, 

or system connected or used in conjunction with the Products; (2) any use that is not designed or intended for the Products; (3

) modi

-

fication, alteration, abuse, misuse, negligence, or accident; (4

) improper storage, installation, maintenance, or operation inc

luding, 

but not limited to, operation of electrical equipment at voltag

es other than the range specified on the Product nameplate; (5) 

any use 

in violation of written instructions or specifications provided 

by Company; (6) any acts of God including, but not limited to, 

fire, water

storms, lightning, or earthquakes; or any theft or riots; or (7) a corrosive atmosphere or contact with corrosive materials suc

h as, but 

not limited to, chlorine, fluorine, salt (provided that indoor a

nd outdoor coils will only be covered if a Sea Coast Kit is ins

talled), sulfur

recycled waste water

, urine, fertilizers, rust, or other damaging substances or chemicals.

• 

Products purchased direct including, but not limited to, Internet or auction purchases and purchases made on an uninstalled bas

is.

• 

Cabinets or cabinet pieces that do not af

fect product performance, air filters, refrigerant, refrigerant 

line sets, belts, wiring, fuses, surge 

protection devices, non-factory installed driers, and Product a

ccessories (unless otherwise specified).

• 

Increased utility usage costs.

REFRIGERANT POLICY

 (

1) Man

ufacturer-Installed Refrig

erant:

 Beginning on Jan

uar

y 1,

 2010,

 R-22 refrig

erant will no long

er 

be used as a man

ufacturer-installed refrig

erant as required b

y f

ederal regulation.

 All Pr

oducts with man

ufacturer-installed refrig

er

-

ant will inc

lude R410-A refrig

erant.

 An

y and all e

xpenses or costs associated with replacing Pr

oduct par

ts that are not R-410A 

compatib

le will not be co

vered b

y the terms and conditions of this limited warranty

. (2) Non-Man

ufacturer installed Refrig

erant:

 For 

Pr

oducts man

ufactured and sold b

y the Compan

y without refrig

erant,

 onl

y man

ufacturer appr

oved and g

en

uine alternate refrig

er

-

ants shall be used.

 The use of contaminated,

 counterf

eit,

 non-g

en

uine

, or non-man

ufacturer appr

oved alternate refrig

erant will v

oid 

this limited warranty

. (3) All Pr

oducts:

 Pr

oducts inc

lude a liquid line filter drier whic

h m

ust be replaced when a compressor replace

-

ment is necessar

y.

 A suction line filter drier m

ust be ad

ded f

or compressor

s defined as b

urnouts and failure to do so will v

oid this 

warranty

. Non-appr

oved refrig

erant and/or non-appr

oved refrig

erant system ad

ditives inc

luding,

 b

ut not limited to d

yes will v

oid 

this limited warranty

ADDITIONAL TERMS:

  

THIS LIMITED 

W

ARRANTY AND LIABILITY SET FOR

TH HEREIN ARE IN LIEU OF ALL O

THER 

W

ARRANTIES AND LIABILITIES,

 

WHETHER IN CONTRA

CT OR IN NEGLIGENCE,

 EXPRESS OR IMPLIED

, IN LA

W OR IN F

A

CT

.  

THE IMPLIED 

W

ARRANTIES OF MER

-

CHANT

ABILITY AND FITNESS FOR A P

AR

TICULAR PURPOSE ARE LIMITED 

TO 

THE DURA

TION OF 

THE APPLICABLE PR

ODUCT 

W

ARRANTY

.  COMP

ANY DOES NO

T A

UTHORIZE ANY PERSON 

TO CREA

TE FOR IT ANY OBLIGA

TION OR LIABILITY IN CONNEC

-

TION 

WITH THE 

PR

ODUCTS.

 

NO

TWITHST

ANDING ANYTHING IN 

THIS LIMITED 

W

ARRANTY 

TO 

THE CONTRAR

Y,

 COMP

ANY SHALL NO

T BE LIABLE FOR 

ANY INCIDENT

AL,

 CONSEQ

UENTIAL,

 INDIRECT

, SPECIAL AND/OR PUNITIVE D

AMA

GES,

 WHETHER B

ASED ON CONTRA

CT

, W

AR

-

RANTY

, T

OR

T (INCLUDING,

 B

UT NO

T LIMITED 

TO

, STRICT LIABILITY OR NEGLIGENCE),

 P

ATENT INFRINGEMENT

, OR O

THER

WISE,

 

EVEN IF AD

VISED OF 

THE POSSIBILITY OF SUCH D

AMA

GES.

 COMP

ANY’S MAXIMUM LIABILITY HEREUNDER IS LIMITED 

TO 

THE 

ORIGINAL PURCHASE PRICE OF 

THE PR

ODUCTS.

 

 

No action ar

ising out of an

y claimed breach of this limited w

arr

anty ma

y be brought b

y a Purchaser more than one (1) y

ear after the 

cause of action has ar

isen.

This limited w

arr

anty giv

es y

ou specific legal r

ights

, and y

ou ma

y also ha

ve other r

ights as otherwise per

mitted b

y la

w

. If this Product is 

considered a consumer product, please be advised that some local la

ws do not allo

w limitations on incidental or consequential damages

, ho

long a w

arr

anty lasts based on registr

ation, or ho

w long an implied w

arr

anty lasts

, so that the abo

ve limitations ma

y not fully apply

. Ref

er to 

your local la

ws f

or y

our specific r

ights under this limited w

arr

anty

.

Consumer Relations

20 Cor

por

ate 

W

oods Dr

Br

idgeton, MO 63044

Or visit our website at

 www

.trane.com

 or 

www

.americanstandardair

.com

 

GW

-658-2314

Tab

le 1B:

 W

arranty 

Time P

eriods f

or Installed Accessories in Air Handler

s and P

ac

ka

g

ed Units

       

CO

VERA

GE 

TERMS FOR RESIDENTIAL APPLICA

TIONS:

 

Pursuant to the 

Tr

ane U

.S

., Inc.

 (“Compan

y”) 

limited w

arr

anty ter

ms and conditions

, the f

ollo

wing Products are co

vered f

or the time per

iods as stated belo

w

.

     Electric Heater

s f

or Multi-P

osition Air Handler

s

HEA

TERS

, Installed in GAM2, GAM5 GA

T2, & 

TAM4 Air Handlers:

 BA

YEA

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

HEA

TERS

, Installed in GAF2 Air Handlers:

 BA

YEC

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

    

HEA

TERS

, Installed in 

TAM7, 

TAM8 & 

TAMG Air Handlers:

 BA

YEV

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     HEA

TERS

, Installed in 4FWCA/F

, 4FWHA/F Air Handlers:

 BA

YHTR, BA

YHTRDS

, BA

YHTRBK  

 

Limited 

W

arr

anty P

er

iod:

 ten(10) y

ears

 

HEA

TERS

, Installed in 

TEM Air Handlers:

 BA

YHTR15

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

HEA

TERS

, Installed in 

TMM Air Handlers:

 BA

YHTRM5

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

HEA

TERS

, Installed in 4TEE & 4TEC Air Handlers:

 BA

YHTR14

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

     Optional Accessories f

or Multi-P

osition Air Handler

s

UVC LIGHTS

, Installed in GAF2, GAM2, GAM5, GA

T2, 

TAM4, 

TAM7 & 

TAM8, 

TAMG Air Handlers:

 BA

YUVC

Limited 

W

arr

anty P

er

iod:

 Ballast - ten (10) y

ears

, Bulbs - one (1) y

ear

     COMPRESSOR CONTR

OL MODULE, Installed in 

TAM8 Air Handlers:

 BA

Y24CCVK

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     Hydronic Heaters f

or Multi-P

osition Air Handlers

HO

W

ATER COIL, Installed in GAM5 Air Handlers:

 BA

YW

AAA05, BA

YW

ABB07 or BA

YW

A

CC08

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     HO

W

ATER COIL, Installed in 

TAM7 & 

TAMG Air Handlers:

 BA

YWV & BA

YW

A

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     HO

W

ATER COIL, Installed in 

TAM8 Air Handlers:

 BA

YWV

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     Electric Heater

s f

or P

ac

ka

g

ed Units

HEA

TERS

, Installed in 4TC*3 & 4, 4WC*3, 4 & 6 P

ac

kaged Units:

 BA

YHTR

V

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

    

HEA

TERS

, Installed in 4WHC P

ac

kaged Units:

 BA

YHTRC

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     Optional Accessories f

or P

ac

ka

g

ed Units

UVC LIGHTS

, Installed in 4TC*3 & 4, 4WC*3, 4 & 6, 4YC*3, 4 & 6, 4DC*4 & 6 P

ac

kaged Units:

 BA

YUV

Limited 

W

arr

anty P

er

iod:

 Ballast - ten (10) y

ears

, Bulbs - one (1) y

ear

     ECONOMIZERS

,  Installed in 4TC*3 & 4, 4WC*3, 4 & 6, 4YC*3, 4 & 6, 4DC*4 & 6 P

ac

kaged Units:

 BA

YECON 

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

 

     MO

TORIZED D

AMPER,  Installed in 4TC*3 & 4, 4WC*3, 4 & 6, 4YC*3, 4 & 6, 4DC*4 & 6 P

ac

kaged Units:

 

BA

YDMPR 

Limited 

W

arr

anty P

er

iod:

 ten (10) y

ears

Summary of Contents for BAYECAA05LG1B

Page 1: ...3A EN Models BAYECAA05LG1B BAYECAA08LG1B BAYECAA10LG1B Table of Contents Section 1 Safety Information 2 Section 2 General Information 3 Section 3 Heater Assembly Labeled 3 Section 4 Install Heater 4 S...

Page 2: ...esting servicing and troubleshooting of this product it may be necessary to work with live electrical components Failure to follow all electri cal safety precautions when exposed to live electrical co...

Page 3: ...use with the air handler 2 Check the components received for damage Report any defects or shortages to the transportation company im mediately 3 Be sure the power supply matches the listing shown on t...

Page 4: ...Coil Compartment Panel and remove the panel Set panel and screws aside STEP 2 Remove the two screws holding the Heater Compartment Panel and remove the panel Set panel and screws aside STEP 3 Remove...

Page 5: ...Blank Off Plate may be discarded STEP 5 Insert heater assembly into heater compart ment 1 Move factory wiring out of the way 2 Slide heater into heater compartment of air handler STEP 6 Attach heater...

Page 6: ...if present STEP 3 Route conduit if used to the entry point and connect 1 Use one hand to secure the conduit nut from inside of the heater compartment 2 Connect field supplied 3 4 conduit to conduit n...

Page 7: ...he terminal block on the heater as illustrated Note Minimum terminal screw torque is 35 in lbs Ground L1 L2 BLACK RED GREEN High Voltage Terminal Block Ground Lug STEP 6 Connect the mating low voltage...

Page 8: ...move the plug from the back of the Heater Panel 2 Attach the wiring diagram included in the documenta tion packet to the back of the heater compartment panel STEP 8 Follow Section 4 Steps 1 3 in rever...

Page 9: ...12300 17 3 BAYECAA08LG1B 1 7 68 26200 32 5 76 19700 27 7 BAYECAA10LG1B 1 9 60 32800 40 7 20 24600 34 6 MINIMUM HEATER AIRFLOW CFM HEATER MATRIX MODEL NO BAYECAA05LG1B BAYECAA08LG1B BAYECAA10LG1B W OUT...

Page 10: ...OD unit 2 R G contacts close on comfort control sending 24VAC to the blower relay 3 Relay contacts 1 and 3 close 4 The blower will now run on the selected speed Speed is field selectable Cooling OD 1...

Page 11: ...ration including but not limited to operation of electrical equipment at voltages other than the range specified on the Product nameplate 5 any use in violation of written instructions or specificatio...

Page 12: ...applications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and...

Reviews: