WSHP-SVX10H-EN
5
Vertical High-Rise Cabinet
WSHP
Digits 1-3: Unit Configuration
GET = High Efficiency Vertical High Rise
Heat Pump
Digit 4: Development Sequence
E
=
R-410A
Digits 5-7: Nominal Size (Tons)
009 = 0.75 Tons
012 = 1 Tons
015 = 1.25 Tons
018 = 1.5 Tons
024 = 2 Tons
036 = 3 Tons
Digit 8: Voltage (Volts/Hz/Phase)
1 = 208/60/1
2 = 230/60/1
7 = 265/60/1
Digit 9: Heat Exchanger
1 = Copper water coil
2 = Cupro-nickel water coil
3 = Copper water coil with Isolation
valve and low flow control
4 = Cupro- nickel water coil with
Isolation valve and low flow control
5 = Copper water coil with isolation
valve and high flow control
6 = Cupro-nickel water coil with isolation
valve and high flow control
Digit 10: Current Design Sequence
Digit 11: Refrigeration Circuit
0 = Heating and cooling circuit
Digit 12: Blower Configuration
1 = Free discharge (factory wire low
speed) - PSC motor
2 = Ducted (factory wire hi speed) - PSC
motor
3 = Free discharge with 1-inch flange -
PSC motor
4 = Free discharge with 3-inch flange -
PSC motor
5 = ECM without flange
6 = ECM with 1-inch flange
7 = ECM with 3-inch flange
8 = Chassis only/No motor (ECM Control)
9 = Chassis only/No motor (PSC Control)
Digit 13: Freeze Protection
A = 20° Freezestat (For Glycol loop)
B = 35° Freezestat (For Water loop)
Digit 14: Open Digit
0 = Open
S = Special
Digit 15: Supply Air Arrangement
0 = Field cut supply air arrangement
1 = Back and front supply air
arrangement
2 = Back and left supply air
arrangement
3 = Back and right supply air
arrangement
4 = Front and left supply air
arrangement
5 = Front and right supply air
arrangement
6 = Left and right supply air
arrangement
7 = Back, front and right supply air
arrangement
8 = Back, front and left supply air
arrangement
9 = Front, right and left supply air
arrangement
B = Back supply air arrangement
L = Left supply air arrangement
R = Right supply air arrangement
T = Top supply air arrangement
F = Front supply air arrangement
Digit 16: Return Air Arrangement
0 = No door
1 = Hinged return air door
3 = Hinged return air door, tamper resistant
(HEX)
4 = Hinged return air door, with key lock
Digit 17: Control Types
C = Tracer
®
ZN510 controls
D = Deluxe 24V controls
H = UC400-B
J = UC400-B with Air-Fi
®
Wireless
Communications
Digit 18: Thermostat Sensor
Location
0 = Wall mounted location
Digit 19: Fault Sensors
0 = No fault sensors
1 = Condensate overflow sensor
2 = Filter maintenance timer
3 = Condensate overflow and filter
maintenance timer
Digit 20: Temperature Sensor
0 = No Additional temperature sensors
1 = Entering water sensor
Digit 21-22: Open Digits
Digit 23: Unit Mounted Disconnect
0 = No unit mounted Switch
C = ON/OFF switch
D = ON/OFF switch with fuses
Digit 24: Filter Type
1 = 1-inch throwaway filter
Digit 25: Acoustic Arrangement
0 = Enhanced sound attenuation
1 = Deluxe sound attenuation
Digit 26: Factory Configuration
3 = R-410A cabinet only w/standard base
4 = R-410A cabinet only w/ 6" extended
base
Digit 27: Paint Color
9 = Light white finish
Digit 28: Outside Air Option
0 = No outside air
Digit 29: Piping Arrangement
B = Back riser location
L = Left hand riser location
R = Right hand riser location
Digit 30: Riser Type
0 = No riser
L = Type L riser
M= Type M riser
Digit 31: Supply Riser
0 = No riser
B = 1-inch riser with insulation
C = 1.25-inch riser with insulation
D = 1.5-inch riser with insulation
E = 2-inch riser with insulation
F = 2.5-inch riser with insulation
G = 3-inch riser with insulation
2 = 1-inch riser
3 = 1.25-inch riser
4 = 1.5-inch riser
5 = 2-inch riser
6 = 2.5-inch riser
7 = 3-inch riser
Digit 32: Return Riser
0 = No riser
B = 1-inch riser with insulation
C = 1.25-inch riser with insulation
D = 1.5-inch riser with insulation
E = 2-inch riser with insulation
F = 2.5-inch riser with insulation
G = 3-inch riser with insulation
2 = 1-inch riser
3 = 1.25-inch riser
4 = 1.5-inch riser
5 = 2-inch riser
6 = 2.5-inch riser
7 = 3-inch riser
Digit 33: Condensate Riser
0 = No riser
B = 1-inch riser with insulation
C = 1.25-inch riser with insulation
D = 1.5-inch riser with insulation
E = 2-inch riser with insulation
F = 2.5-inch riser with insulation
G = 3-inch riser with insulation
2 = 1-inch riser
3 = 1.25-inch riser
4 = 1.5-inch riser
5 = 2-inch riser
6 = 2.5-inch riser
7 = 3-inch riser
Model Number Descriptions