8
HDWA-SVX001D-EN
Model Number Descriptions
Digit 1, 2 — Unit Function
HD
= Agility
™
Centrifugal Water-cooled
Chiller
Digit 3 — Drive
W
= Direct Drive
Digit 4 — Development Sequence
A
Digit 5, 6, 7 — Nominal Compressor
Tonnage
200
= 200 nominal tons
300
= 300 nominal tons
400
= 400 Nominal Tons
SSS
= Special
Digit 8 — Incoming Line Voltage/Unit
Drive Voltage
B
= 208V Incoming Line/460V-60Hz—3Ph
D
= 380V Incoming Line/400V-60Hz—3Ph
F
= 460V Incoming Line/400V-60Hz—3Ph
G
= 480V Incoming Line/400V-60Hz—3Ph
H
= 575V Incoming Line/400V-60Hz—3Ph
J
= 600V Incoming Line/400V-60Hz—3Ph
R
= 380V Incoming Line/400V-50Hz—3Ph
S
= Special
T
= 400V Incoming Line/400V-50Hz—3Ph
U
= 415V Incoming Line/400V-50Hz—3Ph
Digit 9 — Unit Type
A
= Cooling Condenser
S
= Special
Digit 10, 11 — Design Sequence
AA
= Original Design
Digit 12 — Manufacturing Location
L
= La Crosse, Wisconsin
Digit 13 — Hot Gas Bypass
0
= Without HGB
S
= Special
Digit 14 — Control Enclosure
C
= Standard Control Enclosure
D
= Standard Control Enclosure with Tracer
®
SC
S
= Special
Digit 15 — Evaporator Shell Size
A
= 020A Evaporator Shell
C
= 040A Evaporator Shell
S
= Special
Digit 16 — Evaporator Tube Bundle
A
= Evaporator Tube Bundle A
B
= Evaporator Tube Bundle B
C
= Evaporator Tube Bundle C
D
= Evaporator Tube Bundle D
E
= Evaporator Tube Bundle E
S
= Special
Digit 17 — Evaporator Tubes
C
= 0.025 Wall Thickness—0.75 Diameter
Internally Enhanced Copper Evaporator Tube
M
= 0.025 Wall Thickness—0.75 Diameter
High Performance Internal Surface
Evaporator Tube
S
= Special
Digit 18 — Evaporator Waterbox
B
= 150 marine — 2 pass
F
= 150 psi Non-marine, 2-Pass Standard
S
= Special
Digit 19 — Condenser Shell Size
A
= 020A Condenser Shell
C
= 040A Condenser Shell
S
= Special
Digit 20 — Condenser Tube Bundle
A
= Condenser Tube Bundle A
B
= Condenser Tube Bundle B
C
= Condenser Tube Bundle C
S
= Special
Digit 21 — Condenser Tubes
C
= 0.025 Condenser Tube Wall— 0.75
Internal Enhanced Copper Tube
J
= 0.028 Condenser Tube Wall—0.75
Internal Enhanced Copper Tube
S
= Special
Digit 22 — Condenser Waterbox
B
= 150 PDI marine — 2 pass
F
= 150 psi Non-marine, 2-Pass Standard
S
= Special
Digit 23 — Evaporator Expansion
Valve
A
= 400
B
= 200
S
= Special
Digit 24 — Unit Option
B
= Insulation Package and Spring Loaded
Pressure Relief Valve
D
= Spring Loaded Pressure Relief Valve Only
Digit 25 — Control: Generic Building
Automation System (BAS)
0
= None
G
= Generic BAS
Digit 26 — Control: Extended
Operation
0
= None
1
= Extended Operation
Digit 27 — Tracer
®
®
Communication
Interface
0
= None
2
= Tracer
®
Comm 5
3
= Tracer
®
MODBUS
®
4
= Tracer
®
BACnet
®
Digit 28 — Special Options
0
= None
S
= Special Option
Digit 29 — Control: Water Flow
Control
0
= None
W
= Water Flow Control
Digit 30 — Control: Chilled Water
Reset
0
= None
1
= Chilled Water Reset
Digit 31 — Control: Operating Status
0
= None
1
= Operating Status
Digit 32 — Industrial Chiller Package
(INDP)
0
= Without INDP
Digit 33 — Control Power Transformer
(CPTR)
0
= Without CPTR
S
= Special
Digit 34 — Thermal Dispersion Water
Flow Proving
0
= None, Customer to Provide Device for
Condenser and Evaporator
A
= Thermal Dispersion Water Flow Proving
Selected for Condenser and Evaporator