57
• Don't put the decorated board downward to the floor. Putting it against the wall or on the extrusive objects is not
allowed.
• Don't touch the wind deflector or apply force on it, or the wind deflector will have faults.
(1) Check the level of the indoor unit with a flat or filled polyethylene pipe and check that the size of the ceiling hole
is correct. Remove the horizontal gauges before installing the trim panels.
(2) Fix the screws so that the height difference between the two sides of the indoor unit is less than 5mm.
• Install the panel before the need to remove the return air guide,
the method at the same time hold down the two ends of the
button, slowly even pull the guide plate, remove the appropriate
place to prevent damage.
• Install the panel in the direction of the illustration to ensure that
the panel inlet and outlet are corresponding to the inlet and
outlet of the machine.
• Install the two claws into the snap and secure with the screws. (Screw hole position as shown, hidden parts have
been hidden).
• Connect the connector on the right side of the trim panel to the stepped motor wire (10-pin)
• Connect the connector on the left side of the trim panel to the stepped motor wire (5-pin)
• Connect the connector of the lamp panel mounted on the trim panel(9-pin)
• Connect the communication cable, the power cord, and use the controller to check whether the connection is
correct, make sure the machine can be installed after the normal operation of the filter, the return air guide back.
Preparation of Decorated Board
Decorative panels of the line
The installation of the decorative panel in the indoor unit body
nut (provided on site)
washer
hoisting foot
washer
tightening (dual nuts)
[secure hoisting foot]
[secure washer foot]
water level OR polythene tube
claws
snap
right stepper motor
left stepper motor
function indicator
Air leakage
Ceiling
pollution
Water condensate, water dripping
Clearance is not allowed
claws
snap
right stepper motor
left stepper motor
function indicator
Air leakage
Ceiling
pollution
Water condensate, water dripping
Clearance is not allowed