32
Selecting the Mounting Position to Install the Indoor Units
After Selecting The Unit Installation Location, Proceed The Following Steps:
Installation Dimension
Indoor Unit Dimensions (Unit:mm)
• Select suitable places where the outlet air can be sent to the entire room, and
convenient to lay out the connection pipe, connection wire and the drainage pipe to
outdoor.
• The ceiling structure must be strong enough to support the unit weight.
• The connecting pipe, drain pipe and connection wire shall be able to go though the building
wall to connect between the indoor and outdoor units.
• The connecting pipe between the indoor and outdoor units as well as the drain pipe shall
be as short as possible.
• If it is necessary to adjust the filling amount of the refrigerant, please refer to the installation
manual attached with the outdoor unit.
• The connecting flange should be provided by the user himself.
• The indoor unit has two water outlets one of which is obstructed at the factory (with a
rubber cap).
• Only the outlet not obstructed (liquid inlet and outlet side) will be generally used during
installation. If applicable, both the outlets should be used together.
• An access port must be provided during installation of indoor unit for maintenance.
1. Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through
tube purchased locally. The wall hole shall be with a outward down slope of at least 1/100.
2. Before drilling check that there is no pipe or reinforcing bar just behind the drilling position.
drilling shall avoid at positions with electric wire or pipe.
3. Mount the unit on a strong and horizontal building roof. f the base is not firm, it will cause
noise, vibration or leakage.
4. Support the unit firmly.
5. Change the form of the connection pipe, connection wire and drain pipe so that they can go
through the wall hole easily.
Unit Model
A
B
C
D
E
F
G
H
I
4MXD2309BF0R0AA
4MXD2312BF0R0AA
420
892
370
850
185
640
90
760
152
4MXD2318BF0R0AA
4MXD2324BF0R0AA
420
1212
370
1170
185
960
90
1080
152
4MXD2309BF0R0AA
4MXD2312BF0R0AA
4MXD2318BF0R0AA
4MXD2324BF0R0AA
4MXD2309BF0R0AA
4MXD2312BF0R0AA
4MXD2318BF0R0AA
4MXD2324BF0R0AA