Trane 4TTA3030AD000A Service Facts Download Page 1

Service Facts

IMPORTANT — This document contains a wiring diagram, a parts list, and service information. This is customer property and 

is to remain with this unit. Please return to service information pack upon completion of work.

© 2013 Trane

NOTICE:  The manufacturer

 has a policy of continuous product and product data  improvement

 and

 it reserves the right to change design and specifications without notice.

WARNING

!

THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS 

POSSESSING ADEQUATE BACKGROUNDS OF ELECTRICAL AND 

MECHANICAL  

EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR 

CONDITIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND 

OR PROPERTY DAMAGE. THE MANUFACTURER OR SELLER CANNOT 

BE RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION, 

NOR CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE.

CAUTION

!

RECONNECT ALL GROUNDING DEVICES.

ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING 

ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING 

WIRES, SCREWS, STRAPS, CLIPS, NUTS OR WASHERS USED 

TO COMPLETE A PATH TO GROUND ARE REMOVED FOR 

SERVICE, THEY MUST BE RETURNED TO THEIR  ORIGINAL 

POSITION AND PROPERLY FASTENED.

WARNING:

 

HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 

  

CAPACITORS BEFORE SERVICING

CAUTION

!

UNIT CONTAINS R-410A REFRIGERANT!

R-410A OPERATING PRESSURE EXCEEDS THE 
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS 
REQUIRED. FAILURE TO USE PROPER SERVICE 
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR 
PERSONAL INJURY.

SERVICE

USE ONLY R-410A REFRIGERANT AND

APPROVED POE COMPRESSOR OIL.

PRODUCT SPECIFICATIONS

 OUTDOOR UNIT 

 

 

POWER CONNS.

 — V/PH/HZ 

1

 MIN. BRCH. CIR. AMPACITY

 BR CIR PROT RTG – MAX. (AMPS)
 

COMPRESSOR

 NO. USED - NO. SPEEDS

 VOLTS/PH/HZ

 R.L. AMPS 

5

 - L.R. AMPS

 FACTORY INSTALLED

  START COMPONENTS 

6

  INSUL/SOUND BLANKET

  COMPRESSOR HEAT
 

OUTDOOR FAN

 DIA. (IN.) - NO. USED

 TYPE DRIVE - NO. SPEEDS

 CFM @ 0.0 IN. W.G. 

2

 NO. MOTORS - HP

 MOTOR SPEED R.P.M.

 VOLTS/PH/HZ

 F.L. AMPS
 

OUTDOOR COIL

 — TYPE

 ROWS - F.P.I.

 FACE AREA (SQ. FT.)

 TUBE SIZE (IN.)
 

REFRIGERANT

 REFRIGERANT CONTROL

 LBS — R-410A (O.D. UNIT) 

3

 FACTORY SUPPLIED

 LINE SIZE - IN. O.D. GAS 

4

 LINE SIZE - IN. O.D. LIQ. 

4

 

CHARGING SPECIFICATION

 

 TXV SYS CHGD TO SUBCOOL

 CAPILLARY SYS CHGD TO SUPERHEAT
 

DIMENSIONS

 CRATED (IN.)
 

WEIGHT

 SHIPPING (LBS.)

 NET (LBS.)

Tubing lengths in excess of sixty (60) feet see application software.

4TTA3AD-SF-1A

Split System  

Cooling

4TTA3030AD000A, 4TTA3036AD000A, 4TTA3042AD000A, 
4TTA3048AD000A, 4TTA3060AD000A

10/13  

4TTA3042AD000A

380-415/3/50

12

21

SCROLL 

1 - 1

380-415/3/50

6.9 - 52.0

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

3525

1 - 1/6

700

380-415/3/50

0.7

SPINE FIN™

1 - 24

27.86

3/8

R-410A

TXV/Capillary

8 LBS., 6 OZ.

YES

7/8

3/8

10°F

10°F

H  X  W  X  D

46.4 x 35.1 x 38.7

277

240

4TTA3048AD000A

380-415/3/50

12

21

SCROLL

1 - 1

380-415/3/50

7.6 - 51.5

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

3980

1 - 1/6

700

380-415/3/50

0.7

SPINE FIN™

1 - 24

30.79

3/8

R-410A

TXV/Capillary

9 LBS., 13 OZ.

YES

7/8

3/8

10°F

10°F

H  X  W  X  D

51 x 35.1 x 38.7

292

255

4TTA3060AD000A

380-415/3/50

14

25

SCROLL

1 - 1

380-415/3/50

8.9 - 67.1

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

3980

1 - 1/6

700

380-415/3/50

0.7

SPINE FIN™

1 - 24

30.79

3/8

R-410A

TXV/Capillary

9 LBS., 14 OZ.

YES

7/8

3/8

10°F

10°F

H  X  W  X  D

51 x 35.1 x 38.7

297

260

4TTA3030AD000A

380-415/3/50

9

15

SCROLL

1 - 1

380-415/3/50

6.1 - 38.0

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

3525

1 - 1/6

700

380-415/3/50

0.7

SPINE FIN™

1 - 24

24.93

3/8

R-410A

TXV/Capillary

7 LBS., 11 OZ.

YES

3/4

3/8

10°F

10°F

H  X  W  X  D

42.4 x 35.1 x 38.7

217

182

4TTA3036AD000A

380-415/3/50

11

19

SCROLL 

1 - 1

380-415/3/50

6.7 - 43.0

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

3525

1 - 1/6

700

380-415/3/50

0.7

SPINE FIN™

1 - 24

24.93

3/8

R-410A

TXV/Capillary

8 LBS., 8 OZ.

YES

7/8

3/8

10°F

10°F

H  X  W  X  D

42.4 x 35.1 x 38.7

254

219

TUBING INFORMATION

LINE TYPE

REFRIGERANT TO ADD AT SPECIFIED 

ADDITIONAL LENGTH

Suction  Liquid

20 ft

30 ft

40 ft

50 ft

60 ft

3/4"

3/8"

3 oz

9 oz

15 oz

21 oz

27 oz

7/8"

3/8"

3 oz

9 oz

16 oz

22 oz

28 oz

CONTAINS REFRIGERANT!

SYSTEM CONTAINS OIL AND REFRIGERANT UNDER 

HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE 

PRESSURE BEFORE OPENING SYSTEM.
Failure to follow proper procedures can result in personal

illness or injury or severe equipment damage.

CAUTION

!

HOT SURFACE!

DO NOT TOUCH TOP OF COMPRESSOR.

May cause minor to severe burning.

CAUTION

!

1

  Calculated in accordance with Natl. Elec. Codes. Only use 

HACR circuit breakers or fuses.

2

  Standard Air — Dry Coil — Outdoor

3

  This value approximate. For more precise value see unit nameplate.

4

  Max. linear length 80 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid 

60 ft.  For greater length consult refrigerant piping software Pub. 

No. 32-3312-0* (* denotes latest revision).

5

  This value shown for compressor RLA on the unit nameplate 

and on this specification sheet is used to compute minimum 

branch circuit ampacity and max. fuse size. The value shown is 

the branch circuit selection current.

6

  No means no start components. Yes means quick start kit com-

ponents. PTC means positive temperature coefficient starter.

Summary of Contents for 4TTA3030AD000A

Page 1: ...060AD000A 10 13 4TTA3042AD000A 380 415 3 50 12 21 SCROLL 1 1 380 415 3 50 6 9 52 0 NO NO YES PROPELLER 27 6 1 DIRECT 1 3525 1 1 6 700 380 415 3 50 0 7 SPINE FIN 1 24 27 86 3 8 R 410A TXV Capillary 8 L...

Page 2: ...emperature from the unit nameplate 7 Locate this value in the appropriate column of the Sub cooling Charging Table Locate your liquid line temperature in the left column of the table and the intersect...

Page 3: ...L CHARGING CHART CORRECTIONS TABLE FOR LINE LENGTH AND RISE TOTAL REFRIGERANT LINE LENGTH FEET REFRIGERANT LINE LIFT FEET 10 20 25 30 40 60 Use Design Subcool Value 60 50 40 30 25 20 15 10 0 Add 5 Add...

Page 4: ...r Do the start components and run capacitor check good YES Replace the compressor NO Replace start components and or run capacitor NO Check wiring to compressor C S and R Check for high voltage to con...

Page 5: ...REFRIGERANT CIRCUIT 4TTA3030AD 036AD 42AD REFRIGERANT CIRCUIT 4TTA3048AD 060AD Printed from D157826 Printed from D157878 4TTA3AD SF 1A 5...

Page 6: ...1 67 63 AND 59 DEG F INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71 67 63 AND 59 DEG F PRESSURE CURVES FOR 4TTA3030AD GAF2A0A36 Cooling with Thermal Expansion Valve LIQUID PRESSURE PSIG OUTDOOR TEMP...

Page 7: ...71 67 63 AND 59 DEG F INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71 67 63 AND 59 DEG F PRESSURE CURVES FOR 4TTA3036AD GAF2A0A36 Cooling with Thermal Expansion Valve LIQUID PRESSURE PSIG OUTDOOR TEM...

Page 8: ...M 71 67 63 AND 59 DEG F INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71 67 63 AND 59 DEG PRESSURE CURVES FOR 4TTA3060AD MCDB60 Cooling with FCCV or Capillary Tubes LIQUID PRESSURE PSIG OUTDOOR TEMPER...

Reviews: