This Owner’s Manual is given as a guide to good practices in the operation of a wall mounted 
split system. However it does not contain all the service procedures for this unit, as these 
procedures must be performed by a qualified service technician, through the maintenance 
contract with a reputable service company.

Read these operation 

tely before using the air conditioning.

Warranty

Warranty is based on the general terms and conditions by country. The warranty is void if the 
equipment is modified or repaired without the written approval of The Trane Company, if the 
operating limits are exceeded or if the control system or the electrical wiring is modified.

Damage due to inappropriate installation, lack of knowledge or failure to comply with the 
manufacturer’s instructions, is not covered by the warranty obligation.

If the installation does not conform to the rules described in Installation Manual, it may entail 
cancellation of warranty and liabilities by The Trane Company.

Reception

On arrival, inspect the unit before signing the delivery note. Specify any damage of the unit on 
the delivery note, and send a registered letter of protest to the last carrier of the goods within 72 
hours of delivery. Notify the dealer at the same time.

The unit should be totally inspected within 7 days of delivery. If any concealed damage is 
discovered, send a registered letter of protest to the carrier within 7 days of delivery and notify 
the local dealer.

About the Unit

These units are assembled, pressure tested, dehydrated, charged and run tested before shipment.

Refrigerant

The refrigerant provided by the manufacturer complies with all the requirements for our units. 
When using a recycled or reprocessed refrigerant, we recommend its qualities be as good as 
those of a new refrigerant. It is necessary to have the refrigerant tested by a qualified laboratory. 
Failure to do so could void the warranty.

Important

These instructions do not cover all variations in systems, nor do they provide for every possible 
contingency to be met in connection with installation. Should further information be desired or 
should particular problems arise which are not covered sufficiently in this manual, the matter 
should be referred to your authorized Trane dealer.

General Information

MS-SVU42A-EN

instruction comple

Summary of Contents for 2MCW0509G

Page 1: ... SULO 2010 06 69842 1 Inverter Multi split Multi Split 9 000 to 34 000 BTU Hr 4MXW6 A 4TXW6 A ...

Page 2: ... it assume any liability in connection with its use WARNING R410A Refrigerant under Higher Pressure than R22 The units described in this manual use R410A refrigerant which operates at 50 to 70 higher pressures than R 22 Use only R 410A approved service equipment Refrigerant cylinders are painted with pink color to indicate the type of refrigerant and may contain a dip tube to allow for charging of...

Page 3: ...eleased to the atmosphere In particular several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine Fluorine and Carbon CFCs and those containing Hydrogen Chlorine Fluorine and Carbon HCFCs Not all refrigerants containing these compounds have the same potential impact to the environment Trane advocates the responsible handling of all refrigerants incl...

Page 4: ...emote control 9 General operation 11 Optional operation 12 Explanation of special functions 12 Changing batteries 13 Maintenance 14 Cleaning the Front Panel 14 Cleaning the air filters 15 Troubleshooting 1 Operation 1 Emergency Operation 1 Working principle of cooling mode 1 Working principle of heating mode Contents MS SVU42A EN 6 8 8 19 8 ...

Page 5: ...y note Specify any damage of the unit on the delivery note and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery Notify the dealer at the same time The unit should be totally inspected within 7 days of delivery If any concealed damage is discovered send a registered letter of protest to the carrier within 7 days of delivery and notify the local dealer...

Page 6: ... Model Numbers 6 QGRRU 8QLWV 2XWGRRU 8QLW High Efficiency Inverter Multi split R 410A Heat pump 4MXW6509B1 4MXW6512B1 4MXW6518B1 4TXM6518A1 4TXM6524A1 4TXM6528A1 MS SVU42A EN ...

Page 7: ... result in death or serious injury If a burning smell or smoke occurs please turn off the power supply and contact your Trane dealer The unit may be damaged and may cause electric shock or fire Do not use flammable sprays near the air conditioner They can cause a fire or explosion Don t attempt to repair the air conditioner by yourself Incorrect repair could lead to an electric shock or fire so re...

Page 8: ...installation 1DPHV DQG IXQFWLRQV RI HDFK SDUW MS SVU42A EN Ł Ł ņ Ń ł Ņ ń Ň ņ Ņ ł ň ń Ň Ń ň QGRRU XQLW LU LQ LU RXW Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Remote control ...

Page 9: ...CK ƽ Use this button to set up and select temperature options temperature setting TEMP Button TEMP displays the room temperature selected indoor ambient temperature actual room temperature ƽ Press this button the unit will be turned on press it once more the unit will be turned off When turning on or turning off the unit the Timer Sleep function will be canceled HEAT initial value is 28ć Under oth...

Page 10: ... Button ƽ Use this button to decrease the temperature setting Depress the button continuously Button for two seconds to decrease the setting rapidly Release the button to send the setting to the unit and the will be continuously dispalyed Temperature range ć R for Celsius degree setting is 16 30 for Fahrenheit degree setting is 61 86 This temperature adjustment is not available in the AUTO mode Na...

Page 11: ...s SWING UP and DOWN Button To set the TIMER press the Timer On button be certain the clock displays the actual time The ON signal will blink the signal will be concealed and the numerical display will become the timer on setting To adjust the time value of the setting press the or button during the initial 5 second blinking period Each time the or button is pushed the setting will be changed by on...

Page 12: ...ation general operation Guide for operation Optional operation ƾ This function allows removal of moisture on the evaporator of the indoor unit after the unit has stopped in order to prevent mold When the blow function is activated the indoor fan will 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running for about 10 min at low speed In ...

Page 13: ...SRVVLEOH 7DNH RXW WKH ROG EDWWHULHV V VKRZ LQ ILJXUH QVHUW WZR QHZ 9 GU EDWWHULHV DQG SD DWWHQWLRQ WR WKH SRODULW V VKRZ LQ ILJXUH WWDFK WKH EDFN FRYHU RI ZLUHOHVV UHPRWH FRQWURO V VKRZ LQ ILJXUH 1RWH KHQ FKDQJLQJ WKH EDWWHULHV GR QRW XVH ROG RU GLIIHUHQW EDWWHULHV RWKHUZLVH LW FDQ FDXVH WKH ZLUHOHVV UHPRWH FRQWURO PDOIXQFWLRQ 1RWH I WKH ZLUHOHVV UHPRWH FRQWURO ZLOO QRW EH XVHG IRU D ORQJ WLPH SOH...

Page 14: ... in death or serious injury WARNING Hazardous Voltage Disconnect all electric power including remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect power before servicing could result in death or serious injury CAUTION Keep foreign objects away from the fan Make sure you or your children do not put o...

Page 15: ...3 Make sure the batteries in the remote control are working change them if necessary 4 Check the subbase at the outdoor unit If damaged please contact the dealer Maintain after use WARNING Hazardous Voltage Disconnect all electric power including remote disconnects before servicing Follow proper lockout tagout procedures to ensure the power can not be inadvertently energized Failure to disconnect ...

Page 16: ... conditioner is stopped sometimes you may hear the flowing sound of refrigerant Sometimes a thin fog will flow out of the outlet when air conditioner is running under cooling mode This might occur when indoor temperature and humidity are high This is because the indoor air is quickly cooled down After a period of time the fog will disappear with the decrease of indoor temperature and humidity You ...

Page 17: ...il is very low the fan will stop for up to 3 minutes to prevent the delivery of cold air In the HEAT mode frost may accumulate on the outdoor coil due to low outdoor temperature and or high outdoor humidity The unit will automatically switch to defrost mode and the indoor unit will stop blowing air for approximately 8 10 minutes During the defrost cycle moisture may flow from the outdoor unit and ...

Page 18: ... optimum room comfort To stop the unit from operating press the AUTO STOP button once and the unit will shut down Working principle of cooling mode Principle The air conditioner absorbs heat from the room and uses refrigerant to transfer the heat energy to the outdoor unit where it is discharged to the outdoor air Total cooling capacity will increase or decrease based on outdoor ambient temperatur...

Page 19: ...y of the unit to transfer energy The unit will enter Auto Defrost mode and the heating mode will be discontinued for 8 10 minutes During the Auto Defrost cycle the fan motors of the indoor and outdoor units will stop running During the Auto Defrost cycle the indoor indicator flashes and moisture may flow from the outdoor unit and steam may be observed When the defrost cycle is complete the unit wi...

Page 20: ...ffice or e mail us at comfort trane com Literature Order Number Date Supersedes Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice MS SVU42A EN April 2010 New 66129904985 ...