Profile Definition and Network Variables
The following tables are sorted as follows:
•
Tables are listed by unit/profile type and sorted by network variable number.
•
Tables are sorted by name and provide a complete list of names, types, values/ranges, and
descriptions.
N
No
otte
e:: Not all points are available to the user. The available data points are defined during
self-configuration and are dependent on the type of equipment.
ACRB 150–300 Tons Data Points
Table 1. ACRB 150–300 tons configuration parameters
nv Index
Configuration
Variable Name
Variable Type
Variable description
Point Name
2
nciChillerType
UCPT_chiller_type
Chiller Information
Model Information
Enum list - See table in UNVT-UCPT.doc
Model Information
Unit Capacity
Capacity of Unit (in watts)
Chiller Design Capacity
Cooling Type
0 = Water Cooled
1 = Air Cooled
2 to 254 = Unused
Cooling Type
Number of Circuits
Number of Circuits on Unit
Number Of Circuits
Number of Compressors – Crt 1
Number of Compressors on Circuit 1
Number Of Compressors, Circuit 1
Number of Compressors – Crt 2
Number of Compressors on Circuit 2
Number Of Compressors, Circuit 2
5
nciMfgLocation
UCPT_manufacturing_location
Chiller Manufacturing Location
Manufacture Location
6
nciNoiseRdcnReq
SNVT_switch
Default for Noise Reduction Auto/On
Request
Noise Reduction request
7
nciRefrigerant
UCPT_refrig_type
Chiller Refrigerant Type
Refrigerant Type
8
nciCapacityLim
SCPTCapacityLimit
Capacity Limit
Demand Limit Setpoint
9
nciChillerEnable
SCPTChillerEnable
Default Value for nviChillerEnable
Chiller Enable
10
nciCoolsetpt
SCPTCoolSetpoint
Default Value for nviCoolSetpt
Chiller water Setpoint
11
nciDefaults
SCPTDefaultBehavior
Determines which set of values will be
used on power up and communications
failure, stated default values or a list of
manufacturer specified values
Default Values
12
nciDevMajVer
SCPTdevMajVer
The major version number for the device
Software Major Version
13
nciDevMinVer
SCPTdevMinVer
The minor version number for the device
Software Minor Version
15
nciLocation
SCPTlocation
Location Label
Location Label
16
nciMinOutTm
SCPTminSendTime
Minimum Send Time
Minimum Send Time
17
nciMode
SCPTHVACmode
Default Value for nviMode
Chiller Mode
18
nciPwrup
SCPTpwrUpDelay
Power Up Delay
Power Up Delay
19
nciRcvHrtBt
SCPTmaxRcvTime
Receive Heartbeat Time
Receive Heartbeat
20
nciSndHrtBt
SCPTmaxSendTime
Send Heartbeat Time (nciMAXSendTime)
Send Heartbeat
21
nciBuildNum
U16
Device Build Number
Manufacturer-defined
22
nciCRC
UCPT_crc
CRC calculation result
Manufacturer-defined
23
nciDeviceConfig
U16
Device Configuration Choices
Manufacturer-defined