WARNING!

DO NOT OPEN, MAINTAIN OR SERVICE IN AN AREA 
WHERE AN EXPLOSIVE ATMOSPHERE MAY BE 
PRESENT.

IMPORTANT

Read this instruction carefully before installing the 
product

COPYRIGHT

©Tranberg AS 

The information contained in this document remains the 
sole property of Tranberg AS. No part of this document 
may be copied or reproduced in any form or by any 
means, and the information contained within it is not 
to be communicated to a third party, without the prior 
written consent of Tranberg AS. The document, or any 
part of it, may not be translated to any other language 
without the written approval from Tranberg AS.

DISCLAIMER 

Tranberg AS endeavors to ensure that all information in 
this document is correct and fairly stated, but does not 
accept liability for any errors or omissions.

SAFETY PRECAUTIONS

Note that changes made to the product and/or installation 
of components which do not conform to the manufactur-
er’s specification, may be a safety violation. The manufac-
turer will in no circumstance be held responsible for such 
activity. For your health and safety, always use safety gear 
suited for the task. Be certain to follow codes, regulations 
and/or specific procedures that are related to the installa-
tion.

 NAVIGATION LIGHTS 

TEF 2870 E

x

 

NAVIGATION LIGHT

ZONE 2 & SAFE AREA

USER MANUAL

Subject to change without prior notice  

TUM4834  REV. K  03.08.2018

Summary of Contents for TEF 2870

Page 1: ... consent of Tranberg AS The document or any part of it may not be translated to any other language without the written approval from Tranberg AS DISCLAIMER Tranberg AS endeavors to ensure that all information in this document is correct and fairly stated but does not accept liability for any errors or omissions SAFETY PRECAUTIONS Note that changes made to the product and or installation of compone...

Page 2: ...ter intrusion condensation which should be removed immediately When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components At intervals according to company routines the restricted breathing properties should be verified Remove stopping plug at test port PG9 See illustration below INSTALLATION INSTRUCTIONS The navigation light should be in...

Page 3: ... 175 350 58 700 465 55 200 210 NOTE All measurements in millimeters All tolerances 1mm Minimum measurements indicated by an asterix 280A105557 Recommended mounting method of double tier navigation lights LAMP REPLACEMENT WARNING DO NOT OPEN MAINTAIN OR SERVICE IN AN AREA WHERE AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT Use a 19mm wrench to screw off lid Twist off lamp and replace Screw lid back on Tig...

Page 4: ...ted breathing test 5656 Material Brass lens of through coloured glass Input voltage According to installed light bulb Max 230V Light source 40W for 24V versions 65W for 115 230V versions Lamp base P28S Power comsumption 40 65 Watt Ingress protection IP66 Cable gland M20 Ø9 0 14 3mm Area of use Ex zone 2 and safe area Ex classification II3G Ex nR IIC Gc T5 Operating temperature 52 C to 50 C Certifi...