1
© 2010 BioDigit Ltd.
All rights reserved. Multiplication of the document or publication of its content
in any form (including electronic and mechanical implementation) is prohibited
without the written approval of BioDigit ltd.
Safety precautions
You must always observe the technical specifications indicated in the
specifications when using the device. Please always take care of the
environment when putting the device into operation and protect the device
from moisture and direct sunshine.
You may need a soldering iron during installation or putting the device into
operation. Please be careful when executing these operations.
Technical specifications of the device:
Dimensions: 30 × 22 mm
Wiring
M+ / M- and 1 / 5: Motor
red and black (blue) output.
Polarity may be changable
by inserting X1.
2: Yellow, Back light
3: Green, function F1
4: Black, left-hand side rail
6: White, Front light
7: Blue, Supply
(function and light are
common)
8: Red, right-hand side rail
Please do not forget to apply insulation if there is no space for the pins under
the panel. The possibly required resistors (for LEDs) may be installed to this
module also.