X
10-6030/31: TrafiCam - revision R6.00
TI (9 wires) - revision R2.00
TrafiCam PC Tool - version V2.03
TrafiCam firmware - version V2.10
TrafiCam with TI (9 wires)
Manual release:
May 2009
User guide
T
TrafiCam
TI (9 wires)
Page 1: ...0 6030 31 TrafiCam revision R6 00 TI 9 wires revision R2 00 TrafiCam PC Tool version V2 03 TrafiCam firmware version V2 10 TrafiCam with TI 9 wires Manual release May 2009 User guide T TrafiCam TI 9 wires ...
Page 2: ...a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicat...
Page 3: ...r purpose Traficon n v shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material No part of this document may be copied reproduced or translated to another language without the prior written consent of Traficon n v Copyright 2009 Traficon n v All rights reserved Traficon n v Vlamingstraat 19 B 85...
Page 4: ...ation 15 Activate the setup of TrafiCam 16 Advanced settings 18 The failsafe function 18 Detection Recall 18 Quality Recall 18 The filtering functions 19 Inverse direction suppression 19 Camera movement suppression 19 Tree shadow suppression 19 Reflection suppression 19 Other advanced settings 19 Other functions 21 View the detection 21 View live detection on the whole video image 21 View live det...
Page 5: ...e via TrafiCam PC Tool A video image from the sensor allows accurate positioning of multiple presence detection zones TrafiCam provides an input to the traffic light controller upon presence detection Use of the documentation This user guide describes the installation and setup of a TrafiCam system with TI 9 wires as the interface between the TrafiCam sensor PC and traffic controller In addition y...
Page 6: ...Cam system 1 The TrafiCam sensor 2 The mounting accessories 3 Tools hex keys and cable tags 4 The installation CD with the PC tool and the user guides 5 The TI 9 wires interface In addition the installation requires retaining straps connection cables see The cables for connection PSU 12 26 V AC DC ...
Page 7: ...3 W X TrafiCam with TI 9 wires Architecture of the TrafiCam system ...
Page 8: ...ear shell to open the sensor E The rotating point to fix the mounting bracket Front and side view of the TrafiCamsensor B CN1 A C CN2 CN1 CN2 The connectors to the TI 9 wires interface CN1 CN2 pinout see next A The fixation plate to keep the connection cable in its place B The product label C Flattened side of the rear shell as an aid to close the sensor The TrafiCam sensor opened ...
Page 9: ...N2 Pin Description Pin Description Power supply 1 Output 1 Power supply 2 Output 2 Grounding 3 Output 3 A RS 485A 4 Output 4 B RS 485B Ref Common output LED Indication On off Flashing Single flash Double flash Triple flash Off permanently Vehicle presence detection no detection TrafiCam in boot mode Failsafe mode detection recall Failsafe mode quality recall TrafiCam is learning No power ...
Page 10: ...ontroller J5 The PSU connector The tables below illustrate the pinout for connectors J1 and J4 The TI 9 wires interface Pinout of connector J1 Pinout of connector J4 Pin Description Pin Description CAM Power supply Common Common output for output 1 to 4 CAM Power supply Output 1 4 Output 1 to 4 RS 485A RS 485A RS 485B RS 485B Outputs COM Common output ground Outputs 1 Output 1 Outputs 2 Output 2 O...
Page 11: ...2 mm min 5x2 shield min wire d 0 3 mm Interface to PC RS 232 to RS 485 converter cable DB9 serial cable The cables for connection The accessories for mounting There is a mounting bracket for the TrafiCam sensor and a mounting bracket to the pole The tube connects both brackets C A B D A The mounting bracket for the TrafiCam sensor B The tube C The mounting bracket to the pole D The holes to put th...
Page 12: ...ion Step I Mount the TrafiCam sensor on a stable pole Fix the mounting tube to the brackets Torque max 1 3 Nm 1 Fix TrafiCam to the pole using retaining straps 2 Put the retaining straps through the holes in the bracket Position TrafiCam provisionally Torque max 1 3 Nm 3 You can mount TrafiCam in a horizontal or vertical position TrafiCam is a downward looking device ...
Page 13: ...rafiCam side Open the sensor 1 Loosen the cable gland 2 Insert the cable into TrafiCam through the gland 3 Strip the wires and fix the cable tags Isolate the grounding wire 4 Connect the cable to CN1 and CN2 and fix the cable plate 5 Close TrafiCam Torque max 1 0 Nm 6 Tighten the cable gland 7 At the interface side 8 Connect the cable to the connector J1 ...
Page 14: ...ct the interface to the PC Use the RS 232 to RS 485 converter cable and the DB9 serial cable Finally connect the power supply and remove the TrafiCam lens cover You optimise the position of TrafiCam via visual verification TrafiCam PC Tool see next Always verify that there is no horizon in the image Tighten all screws after optimising the position of TrafiCam ...
Page 15: ...truction Frequency Tools Remark Clean the faceplate of TrafiCam Check the camera image Verify the configuration of the system Once per year Once per year Soft cloth and mild detergent PC with TrafiCam PC Tool Avoid movement of TrafiCam Use the setup manual for guidance Depending on the on site conditions you may need to increase the frequency of maintenance ...
Page 16: ...in the CD ROM drive Go to the installation of TrafiCam PC Tool Follow the instructions provided by the installation wizard Click Finish to complete the installation Set the PC port for communication Start TrafiCam PC Tool Select the appropriate COM port as the communication port To verify the COM port Open the Control panel of the PC Select System Hardware Device Manager and then Ports The port is...
Page 17: ...enu item A submenu is indicated via an arrow Close a menu by clicking outside the menu Activate a function Click the function Select a menu item Put the cursor on the menu item Set a parameter for a menu item Put the cursor on the menu item Use the arrow keys or the mouse scroll wheel to make the selection Refresh the sensor image Click Refresh Image from the View menu Set the language Select the ...
Page 18: ...tion mode Zone displayed according to its detection mode presence left stop middle and loop right The factory default setup of the TrafiCam sensor is displayed when you first open TrafiCam PC Tool This default configuration has one presence detection zone C D A B A B C D zone points direction point 1 output number 11 Presence detection zone with zone points and direction points Note To start a new...
Page 19: ...Right click anywhere on the sensor image except on a zone Click the Add Zone pop up Edit the zone as described previously You can place up to 8 presence detection zones To delete a zone right click the zone and click the Delete Zone pop up Set the zone to detect stationary vehicles only stop detection mode Choose Tools Advanced Settings Zone information To set all zones click All Zones and select ...
Page 20: ...on from the File menu The configuration is sent to the TrafiCam sensor This process is displayed in the status bar After sending TrafiCam PC Tool requests and displays the parameters of the activated setup TrafiCam starts a learning cycle The learning cycle takes a few minutes During the learning cycle all presence detection zones are active and the outputs change their status accordingly When you...
Page 21: ...les may stop well in front of or over the stop line OVERLAPPING ZONES To optimise detection two overlapping zones may be used These zones are assigned to the same output Overlapping zones minimize the chance that a car stops in front or behind a zone DETECTION AT NIGHT The detection zones should cover the headlights in every situation At night the detection is on the headlights of the vehicle DIRE...
Page 22: ...on or recall related to detection and a failsafe function related to quality detection recall and quality recall The recall status is indicated via a pop up when you view the detection see View the detection Detection Recall All outputs assigned to recall will change status when there are no vehicles detected during a period defined by the recall activation delay The moment a vehicle is detected a...
Page 23: ...used by continuously moving shadows over the image Default Disabled Selection Disabled Enabled Note You should set one type of suppression only camera movement or tree shadow suppression Do not activate both suppression functions simultaneously Reflection suppression This function suppresses unwanted detection caused by the reflection of headlights Reflection suppression applies only to situations...
Page 24: ...20 W X TrafiCam with TI 9 wires Default 240 s Selection 10 600 s Detection LED You can stop the indicator function of the detection LED Default Enabled Selection Disabled Enabled ...
Page 25: ... Comm Q 100 Information Detection mode Quality image and detection quality see The failsafe function Optimum quality 10 Communication quality between sensor and interface Set the delay and extend time for a zone TrafiCam allows to define a delay time and an extend time for each presence detection zone The delay time is defined as the time between presence detection and the status change of the out...
Page 26: ...r to a presence detection zone see Edit the default presence detection zone You edit the zone as a presence detection zone and an output is assigned However a loop mode zone must have a direction A presence detection zone and a loop mode zone function independently You can place a loop mode zone over a presence detection zone The maximum number of zones presence and loop mode is limited to 8 Selec...
Page 27: ...wish to set the pulse generation parameters for all zones To set the pulse generation parameters per zone select an output from the list Use the arrow keys to set the Pulse Mode the Pulse Time the Delay Time and the Pulse Period Default none Pulse mode Selection none entry exit Default 4 0 s Pulse time Selection 0 1 99 9 s Default 0 s Delay time Selection 0 99 9 s Default 0 0 Pulse period Selectio...
Page 28: ...ange their status accordingly Upgrade firmware Click Upgrade Firmware from the Tools menu Select the firmware file on the PC Click Open The firmware upgrade process takes a few minutes A pop up window displays the status of the process Click Close TrafiCam remains operational during the upgrade process To view product information Select About from the Tools menu A pop up window displays the produc...
Page 29: ...ket fibre reinforced polyamide Tube aluminium COMMUNICATION RS485 service port for configuration OUTPUTS 4 optical coupled dry contacts Imax 50 mA Pmax 300 mW Umax 48 VDC POWER SUPPLY VOLTAGE INPUT 12 26 V AC DC POWER CONSUMPTION 85 mA 12 V DC 1 2 W 50 mA 24 V DC 1 2 W ENVIRONMENTAL Temperature range between 34 C and 80 C 0 to 95 relative humidity non condensing Housing waterproof to IP67 Material...
Page 30: ... DIN rail clickable Mass 100 g COMMUNICATION RS 485 between TI 9 wires PC and TrafiCam OUTPUTS 4 optical coupled dry contacts detection output Pmax 300 mW Imax 50 mA Umax 48 V DC POWER SUPPLY VOLTAGE INPUT 12 26 V AC DC POWER CONSUMPTION 120 mA 12 V DC 1 5 W 60 mA 24 V DC 1 5 W REGULATORY No active components ...
Page 31: ...e angle 3 0 mm 65 95 103 0 to 25 m 0 80 ft Narrow angle 8 0 mm 22 32 39 15 to 75 m 45 250 ft TrafiCam lens specifications Guidelines for the sensor position Height mount TrafiCam as high as possible Position towards the road position TrafiCam overhead if possible If not a side fired position next to the fastest lane is recommended Orientation do not point TrafiCam at the horizon Place the camera i...
Page 32: ...n detection distance 0 ft 3 ft 7 ft 10 ft 3 m 6 m 25 m 25 m 25 m 9 ft 20 ft 80 ft 80 ft 80 ft 4 m 8 m 20 m 25 m 25 m 13 ft 26 ft 66 ft 80 ft 80 ft 5 m 10 m 20 m 25 m 25 m 16 ft 33 ft 66 ft 80 ft 80 ft 6 m 12 m 21 m 25 m 25 m 20 ft 39 ft 69 ft 80 ft 80 ft 7 m 15 m 23 m 25 m 25 m 23 ft 49 ft 75 ft 80 ft 80 ft 8 m 17 m 24 m 25 m 25 m 26 ft 56 ft 79 ft 80 ft 80 ft 9 m 19 m 25 m 25 m 25 m 30 ft 62 ft 8...
Page 33: ...t Maximum detection distance 20 ft 23 ft 26 ft 33 ft 39 ft 49 ft 59 ft 66 ft 82 ft 9 ft 121 ft 250 ft 250 ft 250 ft 250 ft 250 ft 250 ft 250 ft 250 ft 13 ft 62 ft 95 ft 164 ft 250 ft 250 ft 250 ft 250 ft 250 ft 250 ft 16 ft 49 ft 65 ft 91 ft 203 ft 250 ft 250 ft 250 ft 250 ft 250 ft 20 ft 55 ft 72 ft 124 ft 250 ft 250 ft 250 ft 250 ft 250 ft 23 ft 52 ft 65 ft 98 ft 157 ft 250 ft 250 ft 250 ft 250 ...
Page 34: ...m output wiring diagram Appendix 3 Colour code of the cable wires The cables for connection between the TrafiCam device and the interface are not included but can be supplied by Traficon Hereafter you find the wire colour code of the cables which Traficon supplies Cable Wire Colour use with 4TI 1TI STP UV resistant 4 wires shielding use with TI 9 wires STP UV resistant 10 wires shielding BLUE V GR...
Page 35: ...15 setting the output relation 15 TrafiCam changing the output mode 15 P PC port for communication 12 Presence zones adding or deleting a zone 15 assigning an output 15 defining the zone direction 15 delay and extend time 21 detection mode 14 editing the default presence zone 15 guidelines to edit the zones 17 stop detection mode 15 zone ID 15 R Recall 18 detection recall 18 quality recall 18 T Tr...