Trader BEAR BESMOKEY10REM User Manual Download Page 1

Remote control user manual Model:

 

BESMOKEY10REM

Product Specifications

Function

Product Introduction and Pairing

BATTERY 

WARRANTY

LED Indicator

Thank you for purchasing a Trader Remote control. 

Please read the user manual thoroughly and 

familiarize yourself before setting up and using the 

BESMOKEY10REM in the alarm network and save it for 

future reference.

The BESMOKEY10REM works with the BESMOKEY10 with Wireless 
Module (BESMOKEY10WM) installed and also BESMOKEY10BW 
Wireless Smoke Alarm. Set up the network for wireless connection 
and set one of the alarms as the “MASTER” as per the instructions 
for the BESMOKEY10 and BESMOKEY10WM units.  With the master 
alarm set in pairing mode, remove the battery isolation tab on the 
BESMOKEY10REM then press the “NET” button on the remote once 
and the LED will remain on for 30 seconds. It is then connected 
to the Master alarm and the remote LED will flash approximately 
every 30 seconds and enter standby status.

 Note: Press the device 

“Network button” again to exit networking status

TEST Button:

 Press the “Test” button once, LED flash 8 seconds. 

Meanwhile, the device sends the test alarm signal to smoke alarm. 
The smoke alarm received the RF signal, then enters remote test 
status (smoke alarm beeps for 10 seconds and the LED  
flash 5 minute).

Note:

 Use this button to test the product monthly.

LOCATE Button:

 When alarm is sounding and operating in the 

alarm status, press the “Locate” button, the wireless remote alarm 
will enter normal status. The alarm which detected the smoke is still 
beeping. This allows the user quickly determine whether the alarm 
really detected smoke or other particles causing the units to sound.

HUSH Button: 

If the alarms are sounding in alarm mode, locate the 

alarm that has initiated the situation and has detected smoke then 
press the “Hush” button, the LED will flash for 10 seconds, the smoke 
alarm will enter hush for 10 minutes.

SOS Button: 

Press the “SOS” button once to activate the alarm 

network to use them to alert people to a non-fire related 
emergency. The alarms will sound in alarm mode for 1 minute.  
Press the “Locate” button to stop this alarm.

NET (Network) Button:

 First set up one of the smoke alarms as the 

'Master'. Once Master is created: Press the NET button on the remote 
control once to enter pairing mode. The red indicator light on 
remote will illuminate and if pairing is successful, will flash briefly. 

5

Warranty

5

Warranty

Yr

Yr

Power

DC 3V (CR2450) Lithium  

Button Battery

Standby current

≤3uA Operation 

Current

≤30mA

Wireless frequency

433.42MHz

Wireless distance

> 5 metres depending on 

surroundings

Humidity Range

≤95% relative humidity (RH)

Temperature Range

0~45˚C

Low battery

2.5V±0.1V

Battery Lifetime

10 years

Interconnect num.

max. 40 devices 

Size

53 mm x 62 mm x 17mm

COMPLIES WITH

AS/NZS 4268

Network Button

Hush Button

Locate Button

SOS Button

Test Button

LED Indicating