05/20
Product Code: 1096T
Made in China to TQB Brands Pty Ltd specifications
Page 3
Visit us at www.tqbbrands.com.au
PRE-OPERATIONAL SAFETY CHECKS
Please read the following very carefully as failure to comply may invalidate your guarantee. When using electrical appliance basic
precautions should always be followed including below:
The use of gasoline is strictly prohibited. It is a highly volatile fuel that can result in explosions or uncontrolled fires. It is
essential that only kerosene or diesel is used in this unit.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal
injury or loss of life.
Service must be performed by a qualified service agency.
Unvented workshop heaters use air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must
be provided. Refer to instructions.
DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard, a safe
distance away from the heater as recommended by the instructions.
DO NOT use the Workshop Heater in spaces which do or may contain volatile or airborne combustibles, or products such as
gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Direct-fired heaters may cause carbon monoxide (CO) poisoning when incorrectly used, e.g indoors without adequate air
circulation, or if not properly working. CO poisoning may lead to death.
Failure to comply with the precautions and instructions provided with this heater, can result in death, serious bodily injury
and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical
shock.
DO NOT use for home or recreational use.
Please read these instructions before you operate this Workshop Heater
The electrical system to which the appliance is connected must comply with current legislation. Installation requires a residual
current circuit breaker in the main electrical distribution board.
Unplug the appliance before performing any maintenance operations.
Always check the power cable before using the appliance. It must not be bent, taut, stretched, crushed or any way damaged.
The power cable must be replaced by qualified personnel only. Use an original power cable only with a 3-pin approved plug.
DO NOT touch the front outlet is very hot during operation due to high heat.
When servicing, use only TradeQuip identical replacement parts. Use of any other parts will void the warranty. Ensure the
Workshop Heater is disconnected from power before servicing.
Use the right product for the job. There are certain applications for which the Workshop Heater was designed. Do not modify
the Workshop Heater and do not use the Workshop Heater for a purpose for which it was not intended.
INTENDED USE
Ideal for space heating, frost protection and condensation control in commercial and industrial workshops, factories, and
warehouses.
STANDARD OPERATING PROCEDURE
DO NOT use this machine unless you have been trained and assessed to a competent level in its sate use and operation, and
have been given permission to use this
Safety glasses must be worn when operating this
equipment
Long loose hair must be contained when operating
this equipment
Safety footwear must be worn when operating
this equipment
Close fitting/protective clothing must be worn
when operating this equipment
Rings and jewellery must not be worn when
operating this equipment