background image

05/20 

Product Code: 1096T

 

 

 

                  Made in China to TQB Brands Pty Ltd specifications 

Page 3 

Visit us at www.tqbbrands.com.au 

 
 

 
 
 
 
 

 

PRE-OPERATIONAL SAFETY CHECKS 
 
Please read the following very carefully as failure to comply may invalidate your guarantee.  When using electrical appliance basic 
precautions should always be followed including below: 
 

 

The use of gasoline is strictly prohibited. It is a highly volatile fuel that  can result in explosions or uncontrolled fires.  It is 
essential that only kerosene or diesel is used in this unit. 

 

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal 
injury or loss of life.  

 

Service must be performed by a qualified service agency. 

 

Unvented workshop heaters use air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must 
be provided.  Refer to instructions. 

 

DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. 

 

Fire, burn, inhalation, and explosion hazard.  Keep solid combustibles, such as building materials, paper or cardboard, a safe 
distance away from the heater as recommended by the instructions.   

 

DO NOT use the Workshop Heater in spaces which do or may contain volatile or airborne combustibles, or products such as 
gasoline, solvents, paint thinner, dust particles or unknown chemicals. 

 

Direct-fired heaters  may cause carbon monoxide (CO) poisoning when incorrectly used, e.g indoors without  adequate air 
circulation, or if not properly working. CO poisoning may lead to death. 

 

Failure to comply with the precautions and instructions provided with this heater, can result in death,  serious bodily injury 
and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical 
shock.  

 

DO NOT use for home or recreational use. 

 

Please read these instructions before you operate this Workshop Heater 

 

The electrical system to which the appliance is connected must comply with current legislation.  Installation requires a residual 
current circuit breaker in the main electrical distribution board.  

 

Unplug the appliance before performing any maintenance operations. 

 

Always check the power cable before using the appliance. It must not be bent, taut, stretched, crushed or any way damaged. 

 

The power cable must be replaced by qualified personnel only. Use an original power cable only with a 3-pin approved plug.  

 

DO NOT touch the front outlet is very hot during operation due to high heat. 

 

When servicing, use only TradeQuip identical replacement parts. Use of any other parts will void the warranty.  Ensure the 
Workshop Heater is disconnected from power before servicing. 

 

Use the right product for the job. There are certain applications for which the Workshop Heater was designed. Do not modify 
the Workshop Heater and do not use the Workshop Heater for a purpose for which it was not intended.  

 

 

 

INTENDED USE 
Ideal for space heating, frost protection and condensation control in commercial and industrial workshops, factories, and 
warehouses.  

 

 

STANDARD OPERATING PROCEDURE 

DO NOT use this machine unless you have been trained and assessed to a competent level in its sate use and operation, and 
have been given permission to use this 

 

Safety glasses must be worn when operating this 
equipment 

 

Long loose hair must be contained when operating 
this equipment 

 

Safety  footwear  must  be  worn  when  operating 
this equipment 

 

Close  fitting/protective  clothing  must  be  worn 
when operating this equipment 

 

Rings  and  jewellery  must  not  be  worn  when 
operating this equipment 

 

 

Summary of Contents for 1096T

Page 1: ...he Trade reliability TradeQuip branded products offer the very best in performance for an affordable price All backed by a 1year trade guarantee across 1 000 distributors Australia wide WORKSHOP HEATE...

Page 2: ...is equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property Kee...

Page 3: ...and property loss or damage from hazards of fire explosion burn asphyxiation carbon monoxide poisoning and or electrical shock DO NOT use for home or recreational use Please read these instructions be...

Page 4: ...the product is in perfect condition and that there are no visible damaged parts The packaging materials Polyethylene bags polystyrene etc must be disposed of in an appropriate refuse collection contai...

Page 5: ...special fire safety regulations in force in all fields of applications In any case ensure the following minimum safety clearances from materials or objects in the surroundings of the heater Side 0 6 m...

Page 6: ...6 MAINTENANCE Disconnect power prior to any maintenance Before starting any maintenance task shut down unplug and let the heater cool down for at least 15 minutes Regularly wipe the enclosure using a...

Page 7: ...the screen Empty fuel tank dirty or wrong fuel Remove wrong or dirty fuel Fill the tank with clean Diesel or kerosene Fuel filter clogged Clean or replace fuel filter Air leaks in oil line Check hose...

Page 8: ...4 Nozzle Adaptor 1 9 Sealing Ring 1 35 Gas Hose 6 10 Breather Cover 1 36 Oil Hose 1 11 Fuel Tank Cap 1 37 Ignition Needle 1 12 Sealing Ring 1 38 High Voltage Cable 2 13 Tank Cap Shaft 1 39 Air Inlet G...

Page 9: ...ed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not ef...