Revised 6/11/18                              Copyright ©  2018  Trade-Wind Manufacturing, LLC                      Proverbs 22:29                        Page 1 

 

 

***ATTENTION*** 

 

PLEASE REMOVE THE 

RIGHT SIDE BAFFLE 

FILTER TO LOCATE YOUR 

NEW REMOTE CONTROL. 

 

 

 

 

Summary of Contents for I3200 Series

Page 1: ...Revised 6 11 18 Copyright 2018 Trade Wind Manufacturing LLC Proverbs 22 29 Page 1 ATTENTION PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL ...

Page 2: ...Revised 6 11 18 Copyright 2018 Trade Wind Manufacturing LLC Proverbs 22 29 Page 2 ...

Page 3: ...e WARNINGS Instructions must be followed carefully to avoid personal injury IMPORTANT Must be followed carefully to avoid damage or incorrect installation TIPS Contain helpful information to facilitate installation READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufa...

Page 4: ...he cooking area for minimum cross drafts away from doors and windows when possible 2 Ducts must be of adequate size and duct runs should be as short as possible Where turns are necessary keep turning radius as large and as smooth as possible 3 The ducting must be air tight Use a minimum of 2 sheet metal screws at every duct joint Then seal the duct joints with high quality duct tape 4 Do not use t...

Page 5: ...eded Dimensions shown provide minimum clearances unless otherwise specified Important You must provide structural framing and tight backing in the areas in which you are securing the liner inside your custom canopy Failure to do so could distort and damage the liner and void the warranty WARNING For maximum ventilation performance the bottom of the hood or liner should be 30 36 inches 76 2 91 4 cm...

Page 6: ...e liner by placing the filters screws drill bits or drill on the liner s face CONNECTING TO THE VENT PIPE The VSL liner comes with a metal start collar welded in place Attach the Start Collar to the duct with at least three equally spaced screws Also apply duct tape preferably the metal type PART 3 Use and Care WARNING Do NOT operate the blower ventilator system without the filters in place or wit...

Page 7: ... shows all functions of the remote Push the speed or light buttons once to turn on push the same button a second time to turn off You can use the off button to power off the lights and blower simultaneously The 5 minute delay auto off button can be pressed when the blower is on at any speed The blue light behind the speed button will blink showing that this feature has been activated It will conti...

Page 8: ...rical connection of this appliance The electrical installation including minimum supply wire size must comply with the National Electric Code ANSI NFPA 70 1990 or latest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02169 7471 INSTRUCTIONS A 15 to 20 amp electrical service is recomm...

Page 9: ...lating to improperly sized ducting or restrictive roof caps is not covered and will by default be charged back to the Homeowner Light bulbs are not covered under warranty Trade Wind Manufacturing LLC disclaims and excludes any liability for implied warranties or for incidental or consequential damages wherever permitted by law There are no implied warranties of merchantability or fitness for a par...

Page 10: ...een fittings 3 Duct Pipe and Fitting Sizes See Duct Sizing Chart and Area Calculations Section for more detail IMPORTANT No portion of any length of duct pipe or fitting should be smaller than the discharge port of the ventilator This is very important because any type of restriction anywhere in the ventilation system will cause increased static pressure air resistance that may result in rattling ...

Page 11: ...nd that there is no debris blocking the free movement of the damper mechanism Common things to look for include screws protruding into the blade s path overspray of paint plaster and insulation If using rectangular duct be sure that all four sides of the duct are on the outside of the damper s start collar or frame On ventilator installations designed to recirculate the exhaust air back into the k...

Page 12: ... with built in dampers must be made so that when the damper is fully open the actual open area of the final air path is equal to or greater than the discharge port of the ventilator Any undersized portion of a roof cap or wall cap will cause excessive static pressure that may result in rattling vibration and air buffeting noises as well as inadequate ventilation Roof caps and wall caps must have a...