Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: SEPT. 25
th
, 2013 / Rev.: 0.0
INSTALLATION INSTRUCTIONS
TMM 24 Series
AC/DC Switching Power Supply
Order Code *
Input Voltage
Range
Rated Output
Power
Output1
Output2
Recommended
circuit Breaker /
Fuse
TMM 24105 (C)
Nominal:
100
– 240Vac
47
– 440Hz
Operational:
85-264Vac
47
– 440Hz
15W
5Vdc / 3000mA
-
?
TMM 24109 (C)
24W
9Vdc / 2666mA
-
TMM 24112 (C)
12Vdc / 2000mA
-
TMM 24115 (C)
15Vdc / 1600mA
-
TMM 24124 (C)
24Vdc / 1000mA
-
TMM 24212 (C)
+12Vdc / +1000mA
-12Vdc / -1000mA
TMM 24215 (C)
+15Vdc / +800mA
-15Vdc / -800mA
* Option C indicates the unit with chassis mount
Input Current:
@ V
in
= 115Vac
@ V
in
= 230Vac
TMM 24105 (C)
285mA
170mA
TMM 24xxx (C)
425mA
255mA
Operating temperature range:
Natural Air Convection Cooling (20LFM)
-40°C
– +80°C
Over temperature protection:
Shutdown:
Automatic recovery:
at 90°C
at 67°C approx
Output power derating in respect
to ambient temperature:
Model Type
Start of derating
Power derating
TMM 24105 (C)
+60°C
2.5%/K
TMM 24xxx (C)
+60°C
3.75%/K
Storage temperature range / Humidity:
-40°C
– +95°C / 95% rH max.
Over voltage protection (main output only):
120% of V
out
typ.
Connections:
Input / Output terminal:
Screw type terminal: Wires 1.5mm
2
max.
Recommended tightening torque (Used Copper Conductors only,
60/75°C): 0.5 to 0.6Nm (4.4 to 5.3lb.in.)
Pin (TMM 24xxxC):
PCB mounting with solder pins
Internal Fuse:
T2A 250VAC Min.
Case Material:
Plastic Resin + Fiberglass
UL 94V-0 flammability rating
Installation:
1. The following end product enclosures are required; Mechanical, Fire