INSTALLATION INSTRUCTIONS   

 

 

 

 

 

 

TSP BCMU360        Battery Controller

 

 

Output Current

 

Mode 

I

out

 Nominal @ 24V 

I

out

 Nominal @ 48V 

I

out 

Boost @ 24V 

I

out

 Boost @ 48V 

Normal 

15A 

7.5A 

Buffer 

10A* 

5A* 

15A** 

7.5A*** 

  * 

Observe output current de-rating: 2%/°C (B50°C and +60°C for 24V operation or b40°C and +60°C for 48V operation) 

** 

Ambient temperature up to +40°C for max. 10 minutes.     

*** 

Ambient temperature up to +40°C for max. 3 minutes. 

 

User Settings:                                                                                                  Figure 1: 
 

 
 
   

A:    Battery Test Period 10 min (not fitted, default); 15 sec (fitted) 

 

    B:    Output Voltage Settings 48V (not fitted); 24V (fitted, default) 
    C:    Not in use (spare jumper fitted)

 

 
 
 
 

Signal Connector:                                                                                            Figure 2: 

 
Temp.Sensor:

 Connect optional external sensor for automatic end of 

  charge battery compensation. (Traco Power P/N: TSP-TS) 

Battery Remote ON/OFF:

 Enables remote disconnection of the   

battery in buffer mode. 

DC OK: 

Closed contact indicate that the output voltage is higher   

than 85-90% of the nominal output voltage.

 

BAT OK:

 Closed contact indicates that the battery is charged and   

has low resistance. During battery operation, it indicates that the battery   
is approaching disconnection point. 

DC-IN-OK:

 Closed contact indicates that at least one of the inputs is present and has voltage 20 / -3% tolerance. 

Remark:

 Apply torque 0.19Nm for all contacts. 

 

 

 

                                                    Settings 

              Parameter 

Condition 

24V 

48V 

Output Voltage [V] 

Normal Mode 

V

in- 

(0.4…0.8)

 

V

in- 

(0.4…0.7)

 

Output Voltage [V] 

Buffer Mode 

22.2…22.6

 

44.6…45.2

 

Electrical Connections   

& Wire Size 

Input & Output 

2-10 mm

2

 [AWG14-AWG7] 

(Max. resistance 20mΩ) 

1-10 mm

2

 [AWG17-AWG7]       

(Max. resistance 40mΩ) 

Battery Input 

4-10 mm

[AWG11-AWG7]      (Max. resistance 10mΩ ) 

Tightening Torque 

1.76Nm   

Battery Charging Current [A]

 

Normal Mode 

0.8…1.2 

Nominal Battery Voltage [V]

 

25°C Ambient 

13.6 (Factory Set)

 

Battery Adjustment Range [V]

 

Normal Mode 

13.0…14.4

 

Battery Resistance Test [mΩ]

 

Normal Mode 

100 (max) 

Battery Test Current [A] 

Normal Mode 

2.5A for 60ms (typ) 

Battery Test Interval [s] 

Normal Mode 

15s (Jumper A fitted: Fig.1 )          8..10mins (Jumper A not fitted: Fig.1) 

Battery Warning Voltage [V] 

Buffer Mode 

10.4...11.4 

Battery Disconnection Voltage [V] 

Buffer Mode 

9.1…9.7 

Thermal Protection 

Buffer Mode 

100°C (at back of chassis) 

Automatic Battery Temperature 

Compensation Range 

Normal Mode 

-15°C…50°C (external sensor temp. Fig.2) 

Battery Remote ON/OFF 

Buffer Mode 

Switch 5V/5mA (min) to GND (Fig.2) 

Level: 0…1.5V 

Signal Relay Contact Rating 

Input DC Monitoring 

30VDC 1.0A        (Fig.2) 
60VDC 0.5A        (Fig.2) 

A

J6 Link

PCB

C

h

a

s

s

is

Connector

B

J6

C