background image

 

Sihlbruggstrasse 111 CH-6340 Baar, Switzerland

 

Issued: JUNE 9

th

, 2014 / Rev.:2

 

INSTALLATION INFORMATION 

TMSB-2 Series          AC/DC POWER MODULE 

Order Code 

Output Power max.

Output 1(Vo1/Io1) 

Output 2(Vo2/Io2) 

TMSB 2-108 

2 Watts 

8Vdc / 250mA 

--- 

TMSB 2-114 

2 Watts 

14Vdc / 143mA 

--- 

TMSB 2-124 

2 Watts 

24Vdc / 83mA 

--- 

TMSB 2-283*** 

2 Watts 

8Vdc /    *   

3.3Vdc /160mA 

TMSB 2-285*** 

2 Watts 

8Vdc /    * 

5Vdc /250mA 

TMSB 2-2143*** 

2 Watts 

14Vdc / ** 

3.3Vdc /70mA 

TMSB 2-2145*** 

2 Watts 

14Vdc / ** 

5Vdc /83mA 

*Io1+Io2

250mA 

**Io1+Io2

143mA 

***The definition of output power (Po) for dual output modules: Po=Vo1 X (Io1+Io2) 

Input Voltage Range: 

85-264VAC / 50-60Hz 

Input Current: 

50mA typ. at Vin = 115VAC 
30mA typ. at Vin = 230VAC 

Operation Temperature Range: 

-30

~+70

 Max. 

Terminal for 

Wiring: 

PCB mounting with solder pin’s. 

 

 

Internal Fuse: 

T1A 250VAC Min. 

Case Material:  Plastic Resin 

UL 94V-0 flammability rating 

Safety Instructions: 

¾

 

Before installation read these instructions carefully and completely. 

This installation instruction cannot claim for every possible example 

of installation, operation or maintenance. Further information’s are 

obtainable from your local distributor office or from the product data 

sheet which can be downloaded from the Internet at 

http://www.tracopower.com 

¾

 

The power supplies are constructed in accordance with the safety 

requirements of cUL/UL/IEC/EN60950-1 and IEC/EN60335-1. They 

fulfil the requirements of the Low Voltage Directive (LVD) and carries 

the CE-mark. UL and cUL are approved in accordance to UL60950-1, 

and TUV is approved in accordance to IEC/EN60335-1. 

¾

 

Before an installation, maintenance or modification work ensure that 

the main switch is switched off and prevented from being switched 

on again. In case of non-observance touching at any alive 

components or improper dealing with this power supply can result in 

death, severe personal injury or substantial property damage. The 

successful and safe operation is dependent of proper storage, 

handling, installation and operation. 

¾

 

Compliance with the relevant national regulations (in the USA, 

Europe and the other countries) must be observed and ensured. 

Before operation is started the following conditions must be ensured: 

ƒ

  Connection to mains supply in compliance with national 

regulations (VDE0100 and EN50178). 

ƒ

  By use of stranded wires, all strands must be fastened in the 

terminal blocks. 

ƒ

  Power supply and mains cables must be sufficiently fused. 

ƒ

  All output wires must be rated for the power supply output current 

and must be connected with the correct polarity. 

ƒ

  Sufficient cooling must be ensured 

ƒ

  Keep away from fire and water

 

¾

 

Never work on the power supply if power is supplied! 

Risk of 

electric arcs and electrical shock which can cause death, severe 

personal injury of substantial property damage.

 

 

 

¾

 

Warning: 

Hazardous voltages and components storing a very 

substantial amount of energy are present in this power supply during 

normal operating conditions. However, these are inaccessible. 

Improper handling may result in an electric shock or serious burns! 

¾

 

For the assembly information of chosen AC/DC Power Module, see 

the AC/DC Power Module specification and rating label for details: 

ƒ

  Make sure the dimensions of location for assembly complying with 

category or specification datasheet. 

ƒ

  Do not expose the AC/DC Power Module to excessive heat, 

moisture, dust, or corrosive gases.

 

ƒ

  The overall dimensions of AC/DC Power Module shall be 

assembled according to the ventilation designs of end-use 

product.

 

Do not open the power supply until at least 5 minutes after it 

has been disconnected from the mains on all poles. 

 

 

◆  

Avertissement:

Ce bloc d’alimentation contient une grande 

tension et des composants puissants pendant l’utilisation 
normale. Une mauvaise manipulation peut causer un choc 
électrique ou des brûlures graves ! 

◆  

Pour assembler ce module d’alimentation CA/CC, veuillez 
vous référer aux spécifications et la plaque signalétique du 
module CA/CC : 

 

La dimension de l’endroit de l’assemblage doit correspondre 

à la catégorie ou aux spécifications. 

Il ne faut pas exposer ce module d’alimentation CA/CC à la 

chaleur, à l’humidité, à la poussière ou aux gaz corrosifs. 

La dimension générale du module CA/CC doit respecter le 

système de ventilation du produit fini. 

 

Avant d’ouvrir le bloc d’alimentation, attendre au moins 5 
minutes après la déconnexion de tous les pôles 

 

Reviews: