STEP 1

 

- Determine Mounting Location

Proximity - 

• 

The GV628W Tracker Unit should be mounted near an external power source, or in the case of 

temperature tracking, within the reefer fairing.

View of the sky

• 

 - Since the GPS satellites beam location information to the device, it needs to have a view of the 

sky. The GPS signal can penetrate glass, plastic, and wood, but not metal. Here are some suggested locations:

> BEST - Behind a plastic barrier and or glass, shielded from the weather and hidden from view.

> GOOD - Mounted in an open area with direct access to the sky. 

> FAIR - Hidden with an indirect view of the sky.

OPTIONAL Temperature Probe(s) - 

• 

A single probe will usually be located near the return air duct of the 

refrigeration system. The silver tip of the temperature probe is the sensor. It should be exposed directly to the air 

being monitored. Do not cover the sensor, or mount the sensor directly to an exterior wall. Excess wire should be 

coiled (DO NOT cut).  Cables should be secured along the run with clamps or cable ties.

STEP 2

 

- Terminate Electrical Connections

We recommend soldering all electrical connections. If that is not possible, appropriate 

sized wire tap connectors (posi-tap.com) like the ones pictured here should be used. 

Do not jam wires between fuse and fuse holder.

Primary Device Wires 

• 

- There are five wires that need to be connected to an external power source 

RED

RED

/

GREEN

, 2 

BLACK

WHITE

.

>

 

RED

 

is Main power which

 

goes to a constant power connection with a voltage b12V 

and +24V. (Blue wire on trailers, constant battery circuits on other applications)

RED

/

GREEN 

is backup power which goes to a constant power connection with a voltage between 

+12V and +24V. (Trailer Clearance or Parking Lights wire on Trailers, a different constant battery circuit in 

other applications). 

If no alternate power is available, connect to the same source as RED Main wire.

>

  Two 

BLACK

 

wires

 

go  to  chassis  ground 

[Battery(-)] using a ring connector or are tapped 

into an existing ground wire.

>

 

WHITE

 

is for system run detection. For Reefers, 

connect to a circuit that is active only when the 

refrigeration system is in the RUN position. For 

Other  Vehicles  connect  to  a  circuit  that  is  on 

when the engine is running (Key ON). For non-

powered Trailers, connect to a circuit that receives 

power when the tow vehicle is connected.  This 

circuit should be b12V and +24V when 

active, and +0V (or Open) when inactive (see 

the diagram on the next page).

•  Optional Device Wires

 - Temperature Probe 

Equipped Units, connect the GRAY Tracker wire 

to  the  YELLOW  wire(s)  on  the  Temperature 

Probe(s) and connect the BLACK/WHITE STRIPE 

Tracker Wire to both the Red and Green wires 

of the temperature probe(s). The other Tracker 

wires  are  for  optional  I/O  sensors  that  incur 

additional monthly charges. Tape or heat-shrink 

insulate the ends if not in use.

Proper connection of the RED, BLACK, and WHITE wires is essential for the device to operate

Color

Description Comment

Pin #

Red

PWR 1

Primary power input, 8-32V DC

1

Red/Grn

PWR 2

Secondary power input, 8-32V DC

2

Black

GND 1

Primary Ground (to vehicle’s frame) 3

Black

GND 2

Secondary Ground

4

White

Ignition

Ignition input, positive trigger

5

Green

ADIN 1

Analog Input 0-32V

6

Red/White

3V Output

External Acc’y PWR (250mA Max)

7

Black/White

Ground

External Acc’y Ground

8

Gray

1-Wire

Temperature Sensor Input

9

NC

NC

10

Blue

I/O 1

Negative trigger input for normal 

use or open drain output 150mA 

maximum drive current

11

Yellow

I/O 2

12

Brown

I/O 3

13

Orange

I/O 4

14

Purple

EX RX

UART RXD TTL

15

Purple/White

EX TX

UART TXD TTL

16

Pink

RXD

UART RXD TTL

17

White/Black

TXD

UART TXD TTL

18