INSTALLATION AND MAINTENANCE INSTRUCTIONS                                                                 MACERATOR PUMP 

 
Specifications 

Motor:    

 

Seamless can motor, 1/8 hp, thermally protected, ignition protected 

Lead wires:  

 

14 GA 

Fuse:  

 

 

See motor label for fuse size 

Pump Type:  

 

Flexible impeller 

Duty Cycle:  

 

Intermittent duty only 

Ports  

Inlet:  

 

Inlet 1-1/2" (38.1mm) Barb 1-1/2" (38.1mm) 

Outlet:    

1” (25mm) hose barb 

Impeller:  

 

Polyurethane 

Blade:    

 

316 stainless  

Typical Flow:  

 

13 GPM (49.2 LPM) 

Max Amp Draw @ 12v:    11

 

 
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain this pump. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal 
injury and/or property damage! Retain instructions for future reference.  
 

 

READ and UNDERSTAND the Owner's Manual completely before using this Pump. 

Assemble, test and use only in accordance with this Owner's Manual instructions. 
 

Installation 

 
Mounting - 

This pump is self-priming. The pump should be located in an area that is dry and provides ventilation. 

 

 

DO NOT 

locate pump near combustible material. The surface temperature of the motor may exceed 121

 

The pump may be mounted in any position. However, if mounting the pump vertically the pump head should be in the 
down position so that in the unlikely event of a leak, fluid will not enter the motor. 

 

Secure rubber feet with fasteners.  

DO NOT 

compress feet, doing so will reduce ability to isolate vibration and noise. 

 

 

Electrical Connections - 

If the pump is operated in an area containing flammable vapors, the wire leads must be joined by an 

insulated wire connection.  Inadequate wire connections can spark, resulting in explosion, property damage, injury or death. 
 

 

Pump must be protected with proper size fuse as specified on the motor label. 

 

Pump should be operated on a separate circuit. 

 

Pump should be connected to properly sized momentary switch. This prevents pump from damage due to long periods 
of dry run condition. 

 

Switch should be near pump. This will allow operator to hear change in pump sound when tank is empty. 

 
NOTE: For proper operation motor must rotate counterclockwise when viewed from pump end. 

 

Electrical Installation Checklist 

 

Separate circuit from power source 

 

Proper size momentary switch mounted near pump 

 

Proper wire size to length (14g up to 20’ (6.1m), 12g up to 30’ (9.1m)) 

 

Proper fuse size and type (see label on pump) 

 

Insulated wire connectors 