![TR-Electronic SSI-BOX Operating Manual Download Page 23](http://html1.mh-extra.com/html/tr-electronic/ssi-box/ssi-box_operating-manual_1146730023.webp)
Operating Manual SSI-BOX PROFIBUS-DP (PNO)
ELECTRONIC GmbH
TR - ELECTRONIC GmbH,
Global Quality Management, Eglishalde 6, 78647 Trossingen, Tel. ++49 (0)7425-228-0, Fax ++49 (0)7425-228-33
Date: 25.04.2012
TR - E - BA - GB - 0013 - 03
Page 23 of 45
3.6.1.5.1 Use notes
Rotary encoder
SSI without checksum (CRC)
Specified SSI-BOX configuration
Code sequence
arbitrary
Encoder CRC
checksum monitoring switched off
Total measuring range (units) hi
256
Total measuring range (units) lo
0
Revolutions numerator hi
0
Revolutions numerator lo
4096
Revolutions denominator
1
Code SSI-Interface
arbitrary
Code PROFIBUS-Interface
arbitrary
Preset 1 value (units) hi
arbitrary, within the limits
Preset 1 value (units) lo
arbitrary, within the limits
Preset 2 value (units) hi
arbitrary, within the limits
Preset 2 value (units) lo
arbitrary, within the limits
Specified encoder type or programming (without CRC, or switched off)
Increments / Revolution
4096
Measuring range in revolutions
4096
Format
tree-format
Output code
binary
Number of data bits
24
SSI with checksum (CRC)
SSI-BOX configuration
Encoder CRC
checksum monitoring switched on