DSP 402 drive profile
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 44 of 153
TR-EMO-BA-GB-0022 v03
09/29/2020
5.4
“Homing (HM)” operating mode
5.4.1 Control word
Bit CONTROL WORD
0
Value 1:
Switch ready for operation
These bits are used to control
the state machine
1
Value 1:
Enable voltage
2
Value 0:
Decelerate with intermediate
stop ramp
3
Value 1:
Execute operating mode
4
Homing operation start
0 Stop homing procedure
1 Start or continue homing procedure
5-6 not used
7
Transition 0->1: Reset error
8
Halt
0 Enable bit 4
1 Stop axis (0x605D)
9-15 not used
Table 14: Control word (object 0x6040),
“Homing” operating mode