Troubleshooting and diagnosis options
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 150 of 153
TR-EMO-BA-GB-0022 v03
09/29/2020
. . .
0x8210
Protocol error, PDO not processed due to length error
0x8220
Protocol error, PDO length exceeded
0x8611
Position control - following error:
motor blocked, motor load or required acceleration too high
0x9000
External error
– generic error
0xF000
Additional functions
– generic error
0xFF00
Device specific
– generic error
0xFF80
Command can only be executed if the drive operation is enabled.
0xFF81
Command can only be executed if the drive is switched off.
0xFF82
Homing mode is not supported.
Table 37: EMCY Error code, object 0x1003