Select the tab of the device and below the tab "CoE Online".
Select the dictionary type "Online (SDO info)", the object list type "All objects", and press "Update
list".
The dictionary is uploaded now and appears in the object list below, but the values are still empty.
Wait until the progress bar at the bottom of the window disappears, then press "Upload all". Now
the values also appear in the object list.
Without these values "TF-2300_AL CoE SDO information test" will fail to assign the PDOs to the
sync masters and the PDO mappings.
Select the "TF-2300_AL CoE SDO information test" in the tree-view to the left. Select the tab "Test"
to the right and press the button "Start".
If you expand the tree-view, all green circles under this test should become green after a while.
All other test
doesn’t require special preparations or firmware versions. You may run them at any time
in any sequence.