0 or any other value -> A foll.err. only sets the status word bit and sends its
emergency.
While there is a following error, usually the current reaches the current limit, so that
the status bit 2
11
is also set, at least temporarily.
Since the version from "V1.1 17-January-2017" the status bit "Following Error" is only
reset, if the motor is turned on again, or if a fault is cleared, or if the option code is 0 =
"Ignore" and no more following errors occurred during the timeout.
It is not reset when the motor is turned off. Otherwise it would be impossible to find
out, for which reason the drive went to "Fault" or turned itself off.
By clearing the control word bit 2
2
and triggering a quick stop.
The stop method is selected by the option code 0x605A:
5 -> Slow down at the "Profile Deceleration" 0x6084 and stay in quick stop.
6 -> Slow down at the "quick stop Deceleration" 0x6085 and stay in quick stop.
0xC005 -> Slow down at the "Homing Acceleration" 0x609A and stay in quick stop.
0 -> Immediately turn off the drive
1 -> Slow down at the "Profile Deceleration" 0x6084 before turning off the drive.
0xC001 -> Slow down at the "Homing Acceleration" 0x609A before turning off the
drive.
2 or any other value -> Slow down at the "quick stop Deceleration" 0x6085 before
turning off the drive.
When the drive is turned off, it goes to the state DS402 state "Switch-on Disabled".
Before it can be switched back to "Operation enabled" by setting the control word
bit 2
2
again.
By clearing the control word bit 2
2
and triggering a shutdown. The drive goes to the
DS402 state "Ready to switch on", stops and switches off the motor. The stop
method is selected by the option code 0x605B:
0 -> Immediately turn off the drive
1 -> Slow down at the "Profile Deceleration" 0x6084 before turning off the drive.
0xC001 -> Slow down at the "Homing Acceleration" 0x609A before turning off the
drive.
2 or any other value -> Slow down at the "Quick stop Deceleration" 0x6085 before
turning off the drive.