![TR-Electronic LMPI-46 User Manual Download Page 78](http://html1.mh-extra.com/html/tr-electronic/lmpi-46/lmpi-46_user-manual_1146712078.webp)
Commissioning
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 78 of 111
TR - ELA - BA - DGB - 0029 - 00
08/29/2018
5 Commissioning
5.1 Device description file
The XML-based XDD-file contains all information on the measuring system-specific
parameters and the operating modes of the measuring system. The XDD-file is
integrated by the POWERLINK network configuration tool, in order to enable correct
configuration and commissioning of the measuring system.
The XML file is called
"0x0000025C_TR_L-Series-EPL.xdd"
.
Download:
www.tr-electronic.de/f/TR-ELA-ID-MUL-0029
5.2 Bus status display
The POWERLINK measuring system is equipped with four bicolour diagnostic LEDs.
LED 1: POWERLINK Status
(red, green)
LED 2: PORT2, Link/Data Activity (red, green)
LED 3: PORT1, Link/Data Activity (red, green)
LED 4: ENCODER Status
(red, green)
Figure 10: POWERLINK diagnostic LEDs
5.2.1 Indicator states and flash rates
LED states
ON
constantly ON
OFF
constantly OFF
Flickering
Blinking
Single flash
Double flash
Triple flash
Table 2: LED indicator states