6.3.4.7 PROFIdrive-related parameters (PNU 600xx, 9xx)
6.3.4.7.1 Velocity reference value N2/N4 (PNU 60000)
The output speed actual value in the signals
NIST_A
and
NIST_B
is a percentage of the velocity
reference value specified here, also see chapter 6.3.3.17 and 6.3.3.18 on page 126.
PNU
60000
Meaning
Velocity reference value according to N2/N4 normalization
Data type
Float32
Unit
m/min
Default value
120 (100 %)
Access
read/write
Activation
PNU 972
Save
PNU 971
6.3.4.7.2 Velocity measuring unit (PNU 60001)
The
unit
for the output speed is set with this parameter, also see chapter 6.3.3.17 and 6.3.3.18 on
PNU
60001
Meaning
Velocity measuring unit
Data type
Unsigned16
Access
read/write
Activation
PNU 972
Save
PNU 971
Value
Unit
0
Steps/sec
1
Steps/100 msec
2
Steps/10 msec
3
mm/s (rpm)
4
N2/N4 normalized