Parameterization and Configuration
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 112 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
Continued
Bit Function
CL3 CL4
14
Measuring system - park mode activation
0: Normal mode
1: Monitoring and position output of the measuring system are deactivated,
and the measuring system also does not output any further error messages.
The measuring system is inactive on the bus, but the sign-of-life function is
active. This function is required e.g. in order to replace the measuring system,
without having to change the drive configuration.
yes
yes
15
Measuring system - error acknowledgement
1: Error code in signal
G1_XIST2
is deleted (if deletable).
Signal
G1_ZSW
bit 15 indicates that an error acknowledgement is required.
yes
yes
6.3.1.7 Format Signal 10: Status word, Sensor 1 (G1_ZSW)
Status word
G1_ZSW
displays the measuring system status, acknowledgements and error messages
for the basic measuring system functions:
Unsigned16
Bit Function
CL3 CL4
0-10 reserved
-
-
11
Measuring system - error acknowledgement in process
0: No error acknowledgement triggered
1: Error acknowledgement triggered via signal
G1_STW
bit 15
yes
yes
12
Preset function is executed
0: Preset function was not requested
1: Preset function was requested via signal
G1_STW
bit 12
no
yes
13
Cyclic output of absolute position via
G1_XIST2
was requested
0: No querying of absolute position
1: Querying of absolute position was requested via signal
G1_STW
bit 13
yes
yes
14
Measuring system - park mode is active
0: Park mode inactive
1: Park mode was activated via signal
G1_STW
bit 14
yes
yes
15
Measuring system - error present
0: No error present
1: Measuring system error or position error present. The relevant error code is
output via signal
G1_XIST2
, see chapter "6.3.6.1" on page 146. The
acknowledgement or error deletion is made via signal
G1_STW
bit 15.
yes
yes