Installation / Preparation for Commissioning
TR-Electronic GmbH 2018, All Rights Reserved
Printed in the Federal Republic of Germany
Page 100 of 167
TR - ELA - BA - DGB - 0027 - 03
11/12/2019
4.1 Connection
PORT 1
Flange socket M12x1-4 pin D-coded
Pin 1 TxD+, transmission data +
Pin 2 RxD+, received data +
Pin 3 TxD+, transmission data –
Pin 4 RxD–, received data –
PORT 2
Flange socket M12x1-4 pin D-coded
Pin 1 TxD+, transmission data +
Pin 2 RxD+, received data +
Pin 3 TxD+, transmission data –
Pin 4 RxD–, received data –
Supply
Flange connector M12x1-4 pin A-coded
Pin 1 19 – 27 V DC
Pin 2 N.C.
Pin 3 GND, 0 V
Pin 4 N.C.
Shielded twisted pair cables must be used for the supply!
Large shield contact with the mating connector housing must be ensured!
The position and assignment of the connectors, as well as the connection for
the potential equalization, can be found in the accompanying pin assignment!
Order information for the Ethernet plug connector, suitable for flange socket M12x1-4 pin D-coded
Manufacturer
Designation
Order no.:
Binder
Series 825
99-3729-810-04
Phoenix Contact
SACC-M12MSD-4CON-PG 7-SH (PG 7)
15 21 25 8
Phoenix Contact
SACC-M12MSD-4CON-PG 9-SH (PG 9)
15 21 26 1
Harting
HARAX
M12-L
21 03 281 1405