General technical data and installation instructions
TR-Electronic GmbH 2022, All Rights Reserved
Printed in the Federal Republic of Germany
Page 24 of 35
TR-EMO-BA-GB-0023 v00
04/20/2022
5.6 Mechanical
Storage and transport temperature ....................................
-
20…+50 °C
Ambient temperature in operation ......................................
(variant-dependent)
See product data sheet for respective article number
Relative humidity ................................................................
(non-condensing)
≤ 90 %
Protection class ................................................................
(variant-dependent)
See product data sheet for respective article number
Vibration ............................................................................
DIN EN 60068-2-6
MP-
060…MP-180 .......................................................
5 g
MP-200 .......................................................................
10 g
Sine ............................................................................
50…2000 Hz, 60 min
Shock .................................................................................
DIN EN 60068-2-29
Acceleration ................................................................
25 g / 6 ms
Shocks per axis ..........................................................
1000
5.7 Connection instructions
●
Risk of damage to the encoTRive drive system due to incorrect instal-
lation work!
Make sure that the plug connectors are not damaged during installa-
tion. Bent pins can destroy the drive due to short-circuits.
All plug connectors should only be fitted “hand-tight”.
Connection cables must be laid so that damage during operation, e.g.
due to chafing, squeezing or bending, can be excluded.
Tensile stress on cables must be avoided.
The connection configuration can be found in the customer-specific pin assignment.
MP-200 with gear
The protection class with gears PLE60, PLE80, WPLE60 or WPLE80
(or with comparable gears) is IP54, unless specified otherwise in the product data sheet
MP-200 without gear
The housing protection class is IP54, unless specified otherwise in the product data sheet,
the shaft protection class is IP41
MP-
060…180
The protection class is IP40