![TR-Electronic encoTRive MD-025-CO-C Series Manual Download Page 253](http://html1.mh-extra.com/html/tr-electronic/encotrive-md-025-co-c-series/encotrive-md-025-co-c-series_manual_1146659253.webp)
Troubleshooting and diagnosis options
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
05/16/2007
TR - EMO - BA - DGB - 0013 - 00
Page 253 of 260
6.2 EMCY error information
6.2.1 Error register, object 0x1001
The error register specifies the cause of the error in bit code. Several errors can also be displayed
simultaneously by a set bit.
The more detailed error cause can be found in bits 0 - 15 in object 0x1003, see following pages. At the
time of occurrence, an error is indicated by an EMCY message.
Bit
Meaning
0 General
error
1 Current
2 Voltage
3 Temperature
4
Communication error (overflow, status error)
5 Device
profile-specific
6
Reserved, always 0
7 Manufacturer-specific
Table 33: EMCY error register, object 0x1001