6.9 Description of the operating parameters
6.9.1 Count direction
Availability
PNO CLASS1 16 + 32
X
PNO CLASS2 16 + 32
X
TR-Mode Position
X TR-Mode Po Rpm. X
The count direction defines whether ascending position values are output from the
measuring system if the measuring system shaft rotates clockwise or counter-
clockwise (view onto the measuring system flange).
6.9.2 Class 2 Functionality
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
X
TR-Mode Position
TR-Mode Po Rpm.
not supported !
not supported !
not supported !
Defines the functional scope of the measuring system. Class 2 switched off means
only Class 1 functions are active in the measuring system; it does not scale the
position value and is not adjustable.
6.9.3 Commissioning diagnostics
Availability
PNO CLASS1 16 + 32
PNO CLASS2 16 + 32
X
TR-Mode Position
X TR-Mode Po Rpm. X
not supported !
Defines whether the measuring system triggers a
"diagnosis alarm"
(OB82 for
SIMATIC
S7) for an internal error (memory or value jump > 1 revolution), also see
Chapter