Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 128 of 171
TR - ECE - BA - DGB - 0102 - 03
09/23/2014
8.4.3.8 Attribute 18, Position Measuring Increment
Position Measuring Increment
returns the smallest incremental changing of
the position value it is firmly set to 1 step.
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x12
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #18
8.4.3.9
Attribute 19, Preset Value (≤ 32 bit)
This attribute only can be used for preset values ≤ 32 bit. For preset values ≤ 64 bit
the “Attribute 104, Preset Value Extended (≤ 64 bit)” shall be used (see page 142).
Danger of physical injury and damage to property due to an actual value
jump during execution of the preset adjustment function!
The preset adjustment function should only be executed when the
measuring system is stationary, or the resulting actual value jump must be
permitted by both the program and the application!
Preset Value (32 bit)
is used to set the measuring system value to any position
value within the range of 0 to measuring length in increments
–1. If a preset value >
measuring range are executed it is displayed by LED3 (see chapter 6.2 Bus status
display). The output position value is set to the
Preset value
parameter, if the
Set_Attribute_Single
service is executed to this attribute.
DINT, Default: 1000
Preset Value
Byte 0
Byte 1
Byte 2
Byte 3
2
7
up to 2
0
2
15
up to 2
8
2
23
up to 2
16
2
31
up to 2
24
Connection path,
Packed EPATH
with 8 bit class
0x20
0x23
0x24
0x01
0x30
0x13
Logical Type
= Class
Class #23
Logical Type
= Instance
Instance #1
Logical Type
=Attr.-ID
Attr.-ID #19
This attribute is immediately active and saved.
In order to ensure a safe acceptance of the instance attributes
● 12, Direction Counting Toggle
● 16, Measuring Units per Span
● 17, Total Measuring Range in Measuring Units
changes must be first taken over or saved by means of Attribute 112
Accept
Parameter
or the service code 0x16
Save
. In a further step the new
Preset
value