Printed in the Federal Republic of Germany
TR-Electronic GmbH 2013, All Rights Reserved
09/23/2014
TR - ECE - BA - DGB - 0102 - 03
Page 103 of 171
5.1 Connection
X1 = Port 1
X2 = Port 2
EtherNet/IP IN / OUT; Flange socket (M12x1-4 pol. D-
coded)
1
TxD+
transmitted data +
2
RxD+
received data +
3
TxD
–
transmitted data
–
4
RxD
–
received data
–
X3
Supply; Flange connector (M12x1-4 pol. A-coded)
1
11
– 27 V DC Voltage Supply
2
don‘t connect
for service purposes only
3
GND, 0V
Voltage Supply
4
don‘t connect
for service purposes only
Shielded twisted pair cables must be used for the supply!
The shielding is to be connected with large surface on the mating connector
housing!
Order data for Ethernet flange socket M12x1-4 pin D-coded
Manufacturer
Designation
Order no.:
Binder
Series 825
99-3729-810-04
Phoenix Contact
SACC-M12MSD-4CON-PG 7-SH (PG 7)
15 21 25 8
Phoenix Contact
SACC-M12MSD-4CON-PG 9-SH (PG 9)
15 21 26 1
Harting
HARAX
M12-L
21 03 281 1405