10.2 TR - Mode
10.2.1 Object 2001h: TR-Operating parameters, code sequence
The object with index 2001h supports only the function for the code sequence.
The code sequence defines whether increasing or decreasing position values are
output when the measuring system shaft rotates clockwise or counter clockwise as
seen on the flange side.
Index
0x2001
Description
TR-Operating parameters
Data type
UNSIGNED16
Category
Optional
Access
rw
PDO mapping
No
Lower limit
0x0000 = increasing
Upper limit
0x0001 = decreasing
Default
0x0000