9.5 Object 1010h: Store Parameters
This object supports the saving of parameters in non volatile memory (EEPROM).
Changed parameters are accepted only if the storage command is executed! The
storage command is performed if the signature “save” is written to subindex 1.
Index
0x1010
Name
Store parameters
Object code
ARRAY
Data type
UNSIGNED32
Category
Optional
PDO mapping
No
Sub-Index
Description
Value
Data type
Access
0
Number of entries
1
UNSIGNED8
ro
1
Accept and store
parameters
write: 65766173h
read: 1
UNSIGNED32
rw
By read access the device provides information about its saving capability.
Bit 0 = 1, the device saves parameters only on command. That means, if parameters
have been changed by the user and no "Store Parameter Command" had been
executed, at the next power on , the parameters will have there old values.
MSB
LSB
Bits
31-2
1
0
Value
= 0
0
1
In case of write access the device stores the parameters to the non volatile memory.
This procedure takes approx. 3s. In this time the measuring system isn't accessible at
the bus.
In order to avoid storage of parameters by mistake, storage is only executed when a
specific signature is written to the object. The signature is "save".
MSB
LSB
e
v
a
s
65h
76h
61h
73h
On reception of the correct signature, the device stores the parameters. If the storing
failed, the device responds with abort domain transfer: Error code 0606 0000h.
If a wrong signature is written, the device refuses to store and responds with abort
domain transfer: Error code 0800 0020h.