Safety Program Creation - Configuration Example
TR-Electronic GmbH 2016, All Rights Reserved
Printed in the Federal Republic of Germany
Page 104 of 159
TR - ECE - TI - DGB - 0292 - 01
09/20/2016
To define the IP address, go to the directory tree and in the
General
tab select
the directory
PROFINET interface[X1] -> Ethernet addresses
. The IP
address and subnet mask can be set in the mask under
IP protocol
. The IP
address is set by the PG/PC when the project is downloaded.
To configure the access rights for the F-CPU, select the
Protection
directory
in the
General
tab in the directory tree. At least the access level
Full access
(no protection)
should be selected in the mask and a password must be
assigned in the setting
Full access incl. fail-safe (no
protection)
. The password "pw_fcpu" is used in the example project.