Printed in the Federal Republic of Germany
TR-Electronic GmbH 2019, All Rights Reserved
08/20/2021
TR-ECE-BA-GB-0138 v04
Page 27 of 47
Parameter configuration 3:
Temperature class for gas/dust: T6/T80°C
IP protection class IP65 or IP67
Max. limit values allowed for this parameter configuration:
IP
protection
class
IP67
IP65
Speed class
3000 min
-1
6000 min
-1
3000 min
-1
6000 min
-1
Ambient
temperature
50 °C
40 °C
60 °C
50 °C
Power class
6 W
The evaluation shows that there are further limitations in ambient temperatures com-
pared to parameter configuration 2.
6.2 Stainless steel - Explosion protection enclosure
Parameter configuration 1:
Temperature class for gas/dust: T4/T130°C
IP protection class IP65 or IP67
Max. limit values allowed for this parameter configuration:
IP
protection
class
IP67
IP65
Speed class
3000 min
-1
6000 min
-1
6000 min
-1
Ambient
temperature
60 °C
50 °C
40 °C
75 °C
Power class
6 W
3 W
6 W
6 W
The evaluation in case of IP65 shows that there are no restrictions on the absolute
limit values and that the full performance potential of the stainless steel explosion pro-
tection enclosure can be used.
The evaluation in case of IP67 shows that there are limitations in ambient tempera-
tures and power classes.