background image

About the TradeQuip brand 
 
The 'TradeQuip' brand  of  workshop  equipment,  is  designed  for  use  in  a  demanding  workshop 
environment 

by 

professional 

users. 

With 

proven 

and 

trusted “Made  for  the 

Trade” reliability, 'TradeQuip' branded  products  offer  the  very  best  in  performance  for  an 
affordable price. All backed by a 1year trade guarantee across 1,000+ distributors Australia wide.

 

05/20 

Product Code: 1033T 

 
 
 
 
 
 
 
 

 

 
 
 

   

 

           Made in China to TQB Brands Pty Ltd specifications 

 

Visit us at www.tqbbrands.com.au 

 
 
 
 

 

 

 

 

 

 
 
 

 
 

 
 
 

 
 
 

 
 
 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 

 

 

 

 

Product Code: 1033T 

 

AIR CONDITIONER 

Specifications: 

 

Cooling Capacity: 6.5KW / 22200Btu 

 

Power Unit: 240V 50Hz 

 

Rated Power: 3000W 

 

Rated Current: 13.5A 

 

Max. Air Flow: 1200m3 per hour 

 

Noise Level:65dB(A) 

 

Operating Temperature: 18° - 45°C 

 

Suction Pressure: 2.5Mpa (Max.) 

 

Discharge Pressure: 4.5Mpa (Max.) 

 

Speed Control: 2-speed 

 

Refrigerant: R410/800g 

 

Condensation Tank Capacity: 13 Litres 

 

Castor Wheels: 75mm Dia  (2 with brakes) 

 

Dimension:  1245(H) x 640(W) x 560(D) 

 

Nett Weight 100kg 

 

Carton 1of2: 1730 x 740 x 610mm 

 

Gross Weight 155kg 

 
 
 
 
 

Summary of Contents for TradeQuip 1033T

Page 1: ... 1033T Made in China to TQB Brands Pty Ltd specifications Visit us at www tqbbrands com au Product Code 1033T AIR CONDITIONER Specifications Cooling Capacity 6 5KW 22200Btu Power Unit 240V 50Hz Rated Power 3000W Rated Current 13 5A Max Air Flow 1200m3 per hour Noise Level 65dB A Operating Temperature 18 45 C Suction Pressure 2 5Mpa Max Discharge Pressure 4 5Mpa Max Speed Control 2 speed Refrigeran...

Page 2: ...ow this equipment works Failure to observe any of the instructions contained in the manual could result in severe personal injury to the user or bystanders or cause damage to the equipment and property Keep this manual in a convenient and safe place for future reference Whilst every effort has been made to ensure accuracy of information contained in this manual the TQB Brands Pty Ltd policy of con...

Page 3: ...T operate the unit in the presence of flammable substances or vapours such as alcohols pesticides gasoline etc DO NOT use the plug to start and to stop the unit Always use the control panel to start and to stop the unit Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet Always turn the unit off and unplug the main power plug from the electrical outl...

Page 4: ... models are equipped standard with heavy duty castors for easy portability TradeQuip Portable Industrial Air Conditioners bring in air from an outside source to cool its condenser cycling hot air to an outside source This provides a fresh cool air room temperature with high efficiency Just wheel it in plug it in and it goes to work immediately giving high cooling capacity to help wherever and at w...

Page 5: ...suitable fixing tape The outdoor heat extraction duct must be water proof and protected from external debris falling into the exhaust duct point pipe downwards 3 OPERATION 1 Unlock the castors wheels and push the unit using the side handles to a flat level surface and set the castor brakes to the locked position 2 Check the prongs and surface of the power cord plug for dust dirt If dust and or dir...

Page 6: ...pty the water in a resourceful manner and reinstall the condensation tank before restarting Air Conditioner Pipe Drain optional Condensation water may be discharged directly from the Air Conditioner drain pipe Remove the water tank and empty push the optional drain pipe on to the appliance outlet inside the tank recess Then locate the drain pipe through the round hole in the corresponding side pla...

Page 7: ...ir Conditioner is recommended and can be made by an authorised repair facility to ensure that your equipment is in optimum condition and that the equipment has the correct decals and safety labels specified by the manufacturer TROUBLESHOOTING Out of Operation Power Cable loose Fuse is burnt Insert Power Cable into power supply Repair or replace fuse Out of Operation Heat exchange surface is blocke...

Page 8: ...gh Pressure Tube 1 10 Tube Head 2 33 Switch Fix Plate 1 56 Compressor 1 11 Hot Air Ring 1 34 Spiral Case Bracket 1 57 Compressor Cushion 3 12 Angle Protection 4 35 Volute Connection Plate 2 58 Pump Bolt 3 13 Front Shell 1 36 Cold Inlet Tube Assy 1 59 Hot Air Motor Support 1 14 Filter Net 1 37 Lower Motor 1 60 Anterior Spiral Case 1 15 Control Cover Plate 1 38 Spiral Case Fixed Frame 2 61 Wind Mill...

Page 9: ...sed TQB Brands Pty Ltd repair agent This guarantee applies in lieu of any other guarantee expressed or implied and variations of its terms are not authorised Your TQB Brands Pty Ltd guarantee is not effective unless you can produce upon request a dated receipt or invoice to verify your proof of purchase within the 12month period Consumer Guarantee Our goods come with a guarantee that cannot be exc...

Reviews: