background image

 

User's Manual  l  TQMx50UC UM 0101  l  © 2018 TQ-Group 

 

Page  20 

 

 

Table 10: 

COM Express™ Connector Pin Assignment (continued) 

Pin 

Pin-Signal 

Description 

Type 

Remark 

C56 

PEG_RX1– 

PCI Express differential receive pairs 

N/A PCIe on request 

C57 

TYPE1# 

Type 1 Module indication (NC) 

 

 

C58 

 

PCI Express differential receive pairs 

N/A PCIe on request 

C59 

PEG_RX2– 

PCI Express differential receive pairs 

N/A PCIe on request 

C60 

GND(FIXED) 

Ground 

GND   

C61 

 

PCI Express differential receive pairs 

N/A PCIe on request 

C62 

PEG_RX3– 

PCI Express differential receive pairs 

N/A PCIe on request 

C63 

RSVD18 

Reserved 

NC 

 

C64 

RSVD18 

Reserved 

NC 

 

C65 

 

PCI Express differential receive pairs 

N/A 

C66 

PEG_RX4– 

PCI Express differential receive pairs 

N/A 

C67 

RSVD18 

Reserved 

NC 

 

C68 

 

PCI Express differential receive pairs 

N/A 

C69 

PEG_RX5– 

PCI Express differential receive pairs 

N/A 

C70 

GND(FIXED) 

Ground 

GND   

C71 

 

PCI Express differential receive pairs 

N/A 

C72 

PEG_RX6– 

PCI Express differential receive pairs 

N/A 

C73 

GND 

Ground 

GND   

C74 

 

PCI Express differential receive pairs 

N/A 

C75 

PEG_RX7– 

PCI Express differential receive pairs 

N/A 

C76 

GND 

Ground 

GND   

C77 

RSVD18 

Reserved 

NC 

 

C78 

 

PCI Express differential receive pairs 

N/A 

C79 

PEG_RX8– 

PCI Express differential receive pairs 

N/A 

C80 

GND(FIXED) 

Ground 

GND   

C81 

 

PCI Express differential receive pairs 

N/A 

C82 

PEG_RX9– 

PCI Express differential receive pairs 

N/A 

C83 

RSVD18 

Reserved 

NC 

 

C84 

GND 

Ground 

GND   

C85 

PCI Express differential receive pairs 

N/A 

C86 

PEG_RX10– 

PCI Express differential receive pairs 

N/A 

C87 

GND 

Ground 

GND   

C88 

PCI Express differential receive pairs 

N/A 

C89 

PEG_RX11– 

PCI Express differential receive pairs 

N/A 

C90 

GND(FIXED) 

Ground 

GND   

C91 

PCI Express differential receive pairs 

N/A 

C92 

PEG_RX12– 

PCI Express differential receive pairs 

N/A 

C93 

GND 

Ground 

GND   

C94 

PCI Express differential receive pairs 

N/A 

C95 

PEG_RX13– 

PCI Express differential receive pairs 

N/A 

C96 

GND 

Ground 

GND   

C97 

RSVD18 

Reserved 

NC 

 

C98 

PCI Express differential receive pairs 

N/A 

C99 

PEG_RX14– 

PCI Express differential receive pairs 

N/A 

C100 

GND(FIXED) 

Ground 

GND   

C101 

PCI Express differential receive pairs 

N/A 

C102 

PEG_RX15– 

PCI Express differential receive pairs 

N/A 

C103 

GND 

Ground 

GND   

C104 

VCC_12V 

Primary wide power input 

PWR   

C105 

VCC_12V 

Primary wide power input 

PWR   

C106 

VCC_12V 

Primary wide power input 

PWR   

C107 

VCC_12V 

Primary wide power input 

PWR   

C108 

VCC_12V 

Primary wide power input 

PWR   

C109 

VCC_12V 

Primary wide power input 

PWR   

C110 

GND(FIXED) 

Ground 

GND   

Summary of Contents for TQMx50UC

Page 1: ...User s Manual l TQMx50UC UM 0101 l 2018 TQ Group Page i TQMx50UC User s Manual TQMx50UC UM 0101 2018 09 26...

Page 2: ...ironmental Specification 8 3 4 System Components 8 3 4 1 Processor 8 3 4 1 1 Intel Turbo Boost Technology 9 3 4 1 2 Intel Configurable Thermal Design Power 9 3 4 2 Graphics 9 3 4 3 Chipset 9 3 4 4 Mem...

Page 3: ...xternal Effects 24 5 SOFTWARE 25 5 1 System Resources 25 5 1 1 I2C Bus 25 5 1 2 SMBus 25 5 1 3 Memory Map 25 5 1 4 IRQ Map 25 5 2 Operating Systems 26 5 2 1 Supported Operating Systems 26 5 2 2 Driver...

Page 4: ...port 25 Table 12 I2C address mapping COM Express SMBus port 25 Table 13 Acronyms 29 Table 14 Further Applicable Documents and Links 31 ILLUSTRATION DIRECTORY Illustration 1 Block Diagram TQMx50UC 6 Il...

Page 5: ...at brand and trademarks are rightly protected by a third party 1 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Manual is up to date correct complete or of good qu...

Page 6: ...is symbol represents important details or aspects for working with TQ products Command A font with fixed width is used to denote commands contents file names or menu items 1 8 Handling and ESD Tips Ge...

Page 7: ...nts used for example CompactFlash cards are to be taken note of They contain if applicable additional information that must be taken note of for safe and reliable operation These documents are stored...

Page 8: ...Intel Celeron 3765U 2 1 7 GHz 2 MB Cache HD Hyper Threading and Virtualization support 15 W TDP max configurable down to 9 5 10 W Memory DDR3L 1600 dual channel 4 Gbyte and 8 Gbyte memory down config...

Page 9: ...d Temp 0 to 60 C Please visit to TQ Group TQMx50UC for a complete list of standard versions Other configurations are available on request Standard configuration features are CPU version Memory configu...

Page 10: ...s are specified at the COM Express connector Wide input 8 5 V to 20 V maximum input ripple 100 mV VCC_5V_SBY 4 75 V to 5 25 V maximum input ripple 50 mV VCC_RTC 2 0 V to 3 3 V maximum input ripple 20...

Page 11: ...C DC power supplies on the TQMx50UC are switched off The following table shows the power consumption with different processor configurations Table 2 TQMx50UC Power Consumption Mode Standby 5 V Wide in...

Page 12: ...Configurable Thermal Design Power Intel cTDP Intel Enhanced Intel SpeedStep technology Up to 4 Mbyte cache Intel HD Graphics Triple independent displays Table 4 Processor Specifications Mode i7 5650U...

Page 13: ...ive cooling solutions The cTDP can be configured in the uEFI BIOS the default setting is nominal 3 4 2 Graphics The 5th Generation Intel Core 5000U processor series includes an integrated Intel HD gra...

Page 14: ...or GoldCap capacitor backup Temperature compensation 40 C to 85 C Time deviation 0 26 s day 3 0 ppm Time keeping voltage down to 1 5 V Please contact TQ Support for further information about the iRTC...

Page 15: ...AID capability provides high performance RAID 0 1 5 and 10 functionality on up to 4 SATA ports of the SATA host controller Matrix RAID support is provided to allow multiple RAID levels to be combined...

Page 16: ...ed for special functions see 3 4 8 3 5 10 High Definition Audio Interface The TQMx50UC provides a High Definition Audio HDA interface which supports two audio codecs at the COM Express connector The H...

Page 17: ...D24 SER1_RTS 3 3 V output SER1_CTS D25 SER1_CTS 3 3 V input Note Protection circuits In Revision 2 0 of the COM Express specification the signals A98 A99 A101 and A102 have been reclaimed from the VC...

Page 18: ...rmation The following table illustrates some LED boot messages Table 8 LED boot messages Red LED Green LED Remark ON OFF Power supply error ON ON S4 S5 state BLINKING BLINKING S3 state OFF BLINKING uE...

Page 19: ...ntial transmit pairs O A23 SATA2_TX SATA differential transmit pairs O A24 SUS_S5 Indicates system is in Soft Off state Active low output O PD TQ flexiCFG A25 SATA2_RX SATA differential receive pairs...

Page 20: ...pairs 3 O A80 GND FIXED Ground GND A81 LVDS_A_CK LVDS Channel A differential clock O A82 LVDS_A_CK LVDS Channel A differential clock O A83 LVDS_I2C_CK I2C clock output for LVDS display I O A84 LVDS_I...

Page 21: ...n power supply I PU TQ flexiCFG B25 SATA3_RX SATA differential receive pairs I B26 SATA3_RX SATA differential receive pairs I B27 WDT watchdog time out O TQ flexiCFG B28 AC HDA_SDIN2 Serial TDM data i...

Page 22: ...Channel B differential pairs 3 O B79 LVDS_BKLT_EN LVDS panel backlight enable O B80 GND FIXED Ground GND B81 LVDS_B_CK LVDS Channel B differential clock O B82 LVDS_B_CK LVDS Channel B differential cl...

Page 23: ...irs 4 O N A C27 RSVD18 Reserved NC C28 RSVD18 Reserved NC C29 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C30 DDI1_PAIR5 DDI1 DP HDMI DVI differential pairs 5 O N A C31 GND FIXED Ground GND...

Page 24: ...Express differential receive pairs I N A C79 PEG_RX8 PCI Express differential receive pairs I N A C80 GND FIXED Ground GND C81 PEG_RX9 PCI Express differential receive pairs I N A C82 PEG_RX9 PCI Exp...

Page 25: ...ort 1 Clear To Send I PU TQ flexiCFG D26 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D27 DDI1_PAIR0 DDI1 DP HDMI DVI differential pairs 0 O D28 RSVD18 Reserved NC D29 DDI1_PAIR1 DDI1 DP HDMI DV...

Page 26: ...xpress differential transmit pairs O N A D79 PEG_TX8 PCI Express differential transmit pairs O N A D80 GND FIXED Ground GND D81 PEG_TX9 PCI Express differential transmit pairs O N A D82 PEG_TX9 PCI Ex...

Page 27: ...mensions The dimensions of the TQMx50UC are 95 95 mm2 0 2 mm The following illustration shows the Three View Drawing of the TQMx50UC Illustration 2 Three view drawing TQMx50UC The following illustrati...

Page 28: ...he heat spreader acts as a thermal coupling device to the TQMx50UC The heat spreader is thermally coupled to the processor and provides optimal heat transfer from the TQMx50UC to the heat spreader The...

Page 29: ...m Management Bus SMBus The following table shows the I2C address mapping for the COM Express SMBus port Table 12 I2C address mapping COM Express SMBus port 8 bit Address Function Remark 0xA0 0xA4 SPD...

Page 30: ...hipset Components in the Device Manager can be downloaded at this Intel page https downloadcenter intel com download 20775 Intel Chipset Device Software INF Update Utility The Intel Driver Update Util...

Page 31: ...ctrostatic discharge should be arranged directly at the inputs of a system As these measures always have to be implemented on the carrier board no special preventive measures were done on the TQMx50UC...

Page 32: ...QMx50UC 7 6 Packaging By environmentally friendly processes production equipment and products we contribute to the protection of our environment To be able to reuse the TQMx50UC it is produced in such...

Page 33: ...cally Erasable Programmable Read Only Memory EMC Electromagnetic Compatibility eSATA external Serial ATA ESD Electrostatic Discharge FAE Field Application Engineer FIFO First In First Out flexiCFG Fle...

Page 34: ...er RAM Random Access Memory RMA Return Merchandise Authorization RoHS Restriction of the use of certain Hazardous Substances RSVD Reserved RTC Real Time Clock SATA Serial ATA SCU System Control Unit S...

Page 35: ...com download 20775 Intel Chipset Device Software INF Update Utility https downloadcenter intel com download 24345 Intel Driver Update Utility Intel 3 5th Generation Intel Core 5000U series Broadwell U...

Page 36: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l TQ Group...

Reviews: