1.

 

IMPORTANT INFORMATION 

1.1

 

General 

Be sure to follow the tips given in this User's Guide to make best use of the MBox-R/-V/-VH-E39. 
Failure to do so might lead to discomfort or injury, or cause the MBox-R/-V/-VH-E39 to fail. 
 

1.2

 

Symbols and Typographic Conventions 

Table 1: 

Terms and Conventions 

Symbol 

Meaning 

 

This symbol represents the handling of electrostatic-sensitive modules and / or components. These 
components are often damaged / destroyed by the transmission of a voltage higher than about 50 V.  

A human body usually only experiences electrostatic discharges above approximately 3,000 V. 

 

This symbol indicates the possible use of voltages higher than 24 V. 
Please note the relevant statutory regulations in this regard. 
Non-compliance with these regulations can lead to serious damage to your health and also cause 

damage / destruction of the component. 

 

This symbol indicates a possible source of danger. Acting against the procedure described can lead to 

possible damage to your health and / or cause damage / destruction of the material used. 

 

This symbol represents important details or aspects for working with TQ-products. 

 

1.3

 

Before You Start 

This User's Guide must be carefully read and completely understood before you start working with the MBox-R/-V/-VH-E39.  
This User's Guide provides information, which is essential for proper operation of the MBox-R/-V/-VH-E39. General safety 

instructions must be adhered to and only trained and authorized personnel is permitted to work with the MBox-R/-V/-VH-E39. 
 

1.4

 

Duty Of Care 

It must be ensured that the MBox-R/-V/-VH-E39 is only used in environments, which meet the specification of the MBox-R/-V/-

VH-E39. The User's Guide has to be completely read and understood and the personnel is authorized and trained regarding 

standards, regulations and instructions. It also has to be ensured, that the MBox-R/-V/-VH-E39 is mounted, operated and 

maintained according to the instruction of this User's Guide. All applicable national and international regulations and standards 

have to be obeyed. 
 

1.5

 

Limited Warranty 

Parts which wear out naturally are excluded from the warranty beyond that provided by law.  

This applies to e.g., coin cell batteries. 
 

1.6

 

Liability and Warranty Obligation 

TQ-Systems GmbH shall be exempted from the statutory accident liability obligation in case the user does not observe the 

information provided in this User's Guide or the warnings on the device. In the event of damage caused by failure to observe  

the information provided in this User's Guide or the warnings on the device, TQ-Systems GmbH shall not be required to honour 

the warranty even during the warranty period and shall be exempted from the statutory accident liability obligation. 
 

Summary of Contents for MBox-R-E39

Page 1: ...User s Guide l MBox R V VH E39 UG 0100 l 2021 TQ Group Page I MBox R V VH E39 User s Guide MBox R V VH E39 UG 0100 2021 05 25...

Page 2: ...Characteristics 7 4 1 2 Power Consumption Specification 7 4 2 Environmental Specification 7 4 3 Connectors and Interfaces 8 4 3 1 External Connectors and Interfaces Arrangement 8 4 3 1 1 Power Supply...

Page 3: ...R E39 Rear 9 Figure 4 MBox V E39 Rear also valid for MBox VH E39 9 Figure 5 DC Power Supply Connector 10 Figure 6 Mini DP Connector 10 Figure 7 RJ45 Connectors 10 Figure 8 D Sub 9 Adapter Cable 12 Fig...

Page 4: ...you start working with the MBox R V VH E39 This User s Guide provides information which is essential for proper operation of the MBox R V VH E39 General safety instructions must be adhered to and only...

Page 5: ...The MBox R V VH E39 is developed to be safe and effective Power cords power adapters and other features can create potential safety risks that may result in physical injury or property damage especial...

Page 6: ...e should conclude that brand and trademarks are rightly protected by a third party 2 3 Disclaimer TQ Systems GmbH does not guarantee that the information in this User s Guide is up to date correct com...

Page 7: ...R E39 refers to the MBox with a robust housing The MBox R comes in one height with or without serial ports The name MBox V E39 refers to the MBox with a variable housing The MBox V is available in two...

Page 8: ...figurations and individual branding For this reason several other TQMxE39M modules are available on request Table 4 TQMxE39M Module Versions Module CPU Graphics TPM DDR3L SDRAM eMMC Temperature Module...

Page 9: ...MLC Standard Temp 0 C to 70 C 32 64 128 256 512 Gbyte mSATA SATA III MLC Extended Temp 40 C to 85 C Other mSATA flash drives on request Add ons On request e g o WiFi Extended Temp 40 C to 85 C ZigBee...

Page 10: ...red with enough reserve When selecting the power supply the maximum power consumption of all components must be taken into account 4 2 Environmental Specification The following temperature parameters...

Page 11: ...MBox R E39 Front with D Sub 9 Connectors VH version has two additional Sub D connectors Figure 2 MBox V E39 Front without D Sub 9 Connectors MBox VH E39 2 Ethernet 2 Mini DisplayPort Port B with DP su...

Page 12: ...es Arrangement continued Holes for SMA connectors are not supported in standard versions unless otherwise specified Figure 3 MBox R E39 Rear Figure 4 MBox V E39 Rear also valid for MBox VH E39 Antenna...

Page 13: ...it is possible to connect monitors with DP DVI HDMI and VGA input by using dedicated cables and adapters The actual configuration with the Intel Atom E3900 series has extended monitor support with re...

Page 14: ...utton and the Reset Button on the rear side of the MBox R V VH E39 provide the following functions Table 8 Power Button and Reset Button Functions Status Event System response No power supply connecte...

Page 15: ...formation refer to chapter 3 2 and 4 3 2 5 MBox V E39 and MBox VH E39 housings have the holes for SMA connectors as standard 4 3 2 3 Other Optional Connectors For individual solutions more optional co...

Page 16: ...MBox R V VH E39 UG 0100 l 2021 TQ Group Page 13 5 MECHANICS 5 1 Dimensions The following illustrations show the MBox R E39 Figure 10 MBox R E39 Dimensions mm Front View Figure 11 MBox R E39 Dimension...

Page 17: ...ns continued Figure 12 MBox V E39 without D Sub 9 Connectors Dimensions mm Bottom View Figure 13 MBox VH E39 with D Sub 9 Connectors Dimensions mm Bottom View The full height of the housing incl cooli...

Page 18: ...ional clamp for MBox V E39 and MBox VH E39 Directly with screws Please contact support tq group com for more details or ideas suitable for your application Figure 14 MBox R E39 Mounting Dimensions mm...

Page 19: ...ironments IEC 62368 1 2018 Audio video information and communication technology equipment Part 1 Safety requirements 7 WEEE AND RECYCLING 7 1 WEEE TQ Systems GmbH encourages owners to recycle their MB...

Page 20: ...TQ Systems GmbH M hlstra e 2 l Gut Delling l 82229 Seefeld info tq group com l www tq group com...

Reviews: