Page 1: ... JC Electronic Crane Scale User s Guide CRANE SCALE ...

Page 2: ...2 Features Specifications 3 3 Keypad operation 3 4 General Scale Operation 4 5 Battery Charging 5 6 Precaution 5 7 Calibration Method 6 8 Setup Functions in Sub Menu 6 9 Schematics 7 10 Optional Accessories 10 11 Error Information 10 ...

Page 3: ...mum Safe Load 150 Full Scale Display Specifications 5 digit 15 mm Super High Brightness 30 mm red LED display Or 5 digit 40 mm LCD display with back lighting Hanging Fixture 360 degree swirl safe hook shackle Operating Temperature 25 55 Environment Temperature 10 40 Operating Humidity 30 90 RH Auto Power Off 30 minutes after the scale inactive or at extreme low power supply Internal circuit with c...

Page 4: ...SWITCH Press this key to change between Measured Division and Hi resolution Division 3 ZERO Press this key to set the current weight to zero General Scale Operation 1 Turn On the Scale Press the power switch located under the displaying window of scale The scale s maximum weighing capacity is first shown and then the scale goes through a self check sequence 5 seconds later the scale will stabilize...

Page 5: ...he scale will be powered off automatically c After battery charging if there is no display it indicates that either there is difficulty in battery charging or a damaged battery Please contact supplier for repair or replacement To prolong the battery life we suggest you charge the battery after using 48hours or no less than once per week To avoid any damage to the battery please charge it correctly...

Page 6: ...RO Key SPEn Enter into setting state and make sure the scale is with non load 3 Press HOLD Key Set 00000 It will display 00000 after 5 seconds 4 Press HOLD Key to add Press SWITCH Key to move the digit left 3000 Load the scale The closer to full capacity the better For example 3000kg 5 Press ZERO HOLd The scale will record the new calibration data Setup Functions in Sub Menu Function Operation Dis...

Page 7: ...setup Press ZERO Aut 1 0 Manual 1 to Auto press HOLD or Switch to change Sets units Press ZERO CHt 1 0 lb 1 kg Save results Press ZERO YES 0 0 don t save 1 save Press HOLD or SWITCH to change Press ZERO Automatic re start Schematics Dimensions of JC 15T 20T 30T ...

Page 8: ... Model L F C G D JC 15t 897 135 85 270 60 JC 20t 984 150 90 270 73 JC 30t 1072 150 120 310 102 Dimensions of JC 600KG 15T ...

Page 9: ... Model L F C G D JC 600 590 76 47 167 40 JC 1000 590 76 47 167 40 JC 2000 590 76 47 167 50 JC 3000 590 76 50 167 50 JC 5000 683 80 60 176 52 JC 10t 787 90 70 191 52 JC 15t 917 135 85 196 60 ...

Page 10: ... display SW Change the division value between measured division and hi resolution division Note This remote control is optional Please state whether you need the remote on your purchasing order Please extend the antenna before using the remote control Power Source The remote control uses 9V 6F 22 layer built battery Error Information Err0 The calibration data should not less than 4 digits Or the d...

Page 11: ...bration point is too small The valid internal code is from 3000 to 65536 Fault analysis by checking the internal code Press Zero to power on the scale it will first show Ad Then unpress the key it will show the internal code If there is no load on the scale the internal code should be between 6000 and 8000 If the internal code is not in the range from 6000 to 8000 please send the scale back to you...