TPM
207-D533-NN User Manual
40
6.1
Station Alias (4000h)
Index Sub-
Index
Name/Description
Units
Range
Data
Type
Acc
-ess
Default
value
OP
Mode
Save to
EEPROM
4000h Station Alias
01h
Selection
_
0~2
U8
rw
1
All
Yes
(OP)
02h
Setup (High byte)
–
0x00~0xFF
U8
rw
0
All
Yes (OP)
03h
Station Switch
–
0x00~0xFF
U8
ro
–
All
No
04h
Station Alias
–
0x0000~0x0000
U16
ro
–
All
No
Index Sub-
Index
Name/Description
Units
Range
Data
Type
Acc
-ess
Default
value
OP
Mode
Save to
EEPROM
4000h Station Alias
01h
Selection
–
0~2
U8
rw
1
All
Yes
how to set a station alias (Default is 1)
Value
Definition
0
The value saved at 004h in the
SII
is set as station alias.
1
The value made of object 4000h:02h and dip switch of amplifier is set as station
alias.
(*1)
2
Read station alias via AL control word
(*1) If Setting values for both the dip switch and object 4000h:02 are 0, the value of the SII area (0004h) is regard as
Station Alias.
02h
Setup (High byte)
–
0x00~0xFF
U8
rw
0
All
Yes (OP)
High byte of Station Alias
How to set the parameters with dip switch and object 4000h:02h
Station Alias (16 bits)
High byte
Low Byte
Value set by
4000h:02h
Value set by dip switch
03h
Station Switch
–
0x00~0xFF
U8
ro
0
All
No
This parameter is to show the value of Station ID Switch which is in front of device. This value will be refreshed when the
switch is changed.
04h
Station Alias
–
0x0000~0x0000
U16
ro
0
All
No
This parameter is to show the station alias which will be refreshed After power on.