TPI FPQ 3310 Series Installation Instructions Download Page 1

1

1. 

LOCATION OF HEATER:

A.  Heater  is  mounted  on  the  wall  near  ceiling  or  floor,  air  flow  down.

  CAUTION: Do not obstruct the front grille of the heater with curtains, 

  furniture, etc., since the proper operation of the  heater  requires  a  free 

  flow intake and exhaust of air.

B.  Minimum  mounting  height  is  10”  above  finished  floor.

C. For surface mounting use adapter FPQ/3310EX33.

2. 

BEFORE MOUNTING:

A.  Insure that the supply voltage matches voltage rating on the label of the

 heater.

B.  Turn off electrical power to heater circuit.

3. 

MOUNTING INSTRUCTIONS:

A. 

Disassemble heater by removing 7 screws “C” as shown in Figure 1 and 2

.

B.  Flush mounting, see Fig. 1.

  Place rough-in box “A” between studs at desired height: secure to studs 

  through  holes  “M”. The  flanges  on  the  rough-in  box  must  rest  on  the 

  surface of the finished wall; if the box is installed prior to the application 

  of  the  finished  wall,  allowance  must  be  made  for  the  wall  thickness.

C. Surface mounting, See Fig. 2.

  Insert rough-in box “A” into surface adapter “E”. 

  Secure the heater rough-in box to wall at desired height through holes 

“X”. Be sure that the rough in box is 

  centered in surface adapter. For surface mounting, bring wiring through 

  bottom knockout “K” only.

D. Place assembly “B” into rough-in box “A”. Secure with six screws “C”.

4. 

WIRING INSTRUCTIONS REF: Diagrams WD1, WD2, WD3, WD4.

A.  Field Conversion for Lower Wattage: All units are factory wired for higher 

  wattage rating. (See paragraph 9 for conversion to lower wattage rating). 

B.  Bring service leads through knockout “K” on top or bottom of rough-in 

  box for flush or semi-recessed mounting, bottom knockout “K” only for 

  surface  mounting.  When  wiring  from  the  bottom,  install  wire  through 

  cover “G” by removing screw “H”.

C. Attach service leads to two black leads on 208-240 volt models and to 

  black and white leads on 120-277 volt models, attach ground lead to

  green wire with approved connectors. Comply with all national and local 

 codes.

D. Attach  wiring  compartment  cover  “D”  to  assembly  with  screw  “C”.

5. 

FINAL STEPS:

A. Clean all construction dirt and debris from inside heater.

B.  Attach front grille “F” with four screws “L”. A parts bag containing the 

  cover  screws  and  the  thermostat  knob  is  located  inside  of  heater.

C. Attach thermostat knob “T”.

6. 

OPERATING INSTRUCTIONS:

A.  Turn on power at the circuit breaker panel.

B.  If  there  are  two  controls  on  the  front  grille  of  the  heater;  the  one  on 

  your    left  “T”  is  the  thermostat  control  and  should  be  set  to  the 

  position  to  give  the  desired  comfort  heat  in  the  room.  The  switch  on 

  your  right  is  the  mode  selection  switch.  Two  modes  of  heating 

  operation  are  available:  CONSTANT:  Fan  runs  continuously  while 

  thermostat  cycles  heating  elements  on  and  off  as  required  by 

  setting;  and  AUTO:  Fan  and  heating  elements  cycle  on  and  off 

  simultaneously  on  thermostat  control.  The  fan  can  be  operated 

  separately to circulate room temperature air by  turning thermostat to its 

  lowest setting and placing  fan  selector  switch  in  the  “CONSTANT”

 

position.

C. After the desired temperature is reached, turn thermostat stem counter 

 

clockwise until a click is heard from the thermostat.

D.  Models  with  double  pole  thermostats:  Turn  thermostat  adjustment 

  knob fully counter-clockwise to the “OFF” position . This will d-energize 

  the heating element and fan.

FPQ

3310 SERIES

INSTALLATION

 INSTRUCTIONS 

FIG. 1 FLUSH MOUNT

FIG. 2 SURFACE MOUNT

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

X

F

Y

L

10" OR (254)mm

MINIMUM TO

FINISHED FLOOR

E

SERVICE CABLE

OR CONDUIT

K

G

H

C

D

P

Q

10" OR (254)mm

0"

0"

0"

Form 9821 

ECO 1-7472 

REV. 10-19-18

19 1/2

(490.5 m

m

)

14 1/8

(362 mm)

10" OR (254)m

m

MINIMUM TO

FINISHED FLOOR

A

P

L

F

C

D

Y

H

G

K

Q

Summary of Contents for FPQ 3310 Series

Page 1: ...ce leads to two black leads on 208 240 volt models and to black and white leads on 120 277 volt models attach ground lead to green wire with approved connectors Comply with all national and local codes D Attach wiring compartment cover D to assembly with screw C 5 FINAL STEPS A Clean all construction dirt and debris from inside heater B Attach front grille F with four screws L A parts bag containi...

Page 2: ...nect panel or operate internal disconnect switch if provided 8 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric chock or fire or damage the heater 9 To prevent a possible fire do not block air intakes or exhaust in any manner 10 A heater has hot and arcing or sparking parts inside WARNING Do not use it in area where gasoline paint or ...

Page 3: ... 120 750 6 25 HF3315RP 240 208 3000 2250 12 5 10 8 240 208 1500 1125 6 25 5 4 HF3316RP 240 208 4000 3000 16 7 14 4 240 208 2000 1500 8 3 7 2 FIGURE 3 WD 1 3310 with Summer Fan Switch Double Pole T Stat and Optional Disconnect Switch WD 2 3310 with Summer Fan Switch Single Pole T Stat and Optional Disconnect Switch WD 3 3310 with Optional Double Pole T Stat and Disconnect Switch WD 4 3310 with Sing...

Page 4: ... MODÈLE TENSION PUISSANCE AMPÉRAGE E3313RP 120 1500 12 5 120 750 6 25 HF3316RP 240 208 3000 2250 12 5 10 8 240 208 1500 1125 6 25 5 4 HF3316RP 240 208 4000 3000 16 7 14 4 240 208 2000 1500 8 3 7 2 FIGURE 3 WD 1 3310 avec commutateur pour ventilateur d été thermostat bipolaire et interrupteur optionnel WD 2 3310 avec commutateur pour ventilateur d été thermostat unipolaire et interrupteur optionnel...

Reviews: