4.1.2 HIGH CO ALARM
Should the CO reading rise above 2,000ppm a continuous series of Alarm Beeps
will be heard. This Alarm alerts the user that there is a high concentration of CO
and that there may be a potential problem with the appliance. The instrument will
continue to monitor CO up to 10,000ppm but the longer the probe is left attached
to the instrument sampling at these high levels the longer the recovery time back
to ambient air before the instrument will be able to be switched off (see 4.1.7
–
Failsafe Turn Off).
4.1.3 Screen 2
Displays Oxygen (O
2
) reading in percentage (%)
Displays calculated Excess Air (X Air) figure in
percentage (%)
Displays calculated Efficiency (Eff.) figure in percentage
(%)
Pressing the Up Arrow Key will toggle between
the Fuel Options
Pressing the Down Arrow Key will toggle
between the Efficiency Options
4.1.4 Screen 3
Displays Carbon Monoxide (CO) reading in parts per
million (ppm)
Displays Oxygen (O
2
) reading in percentage (%)
Pressing the Up Arrow Key will toggle between
the Fuel Options
Pressing the Down Arrow Key will toggle
between the Efficiency Options