When the Tightness Test starts the
Live Pressure Reading
is displayed on the top line,
tItn
on the middle line
and the
Timer
on the bottom line.
Once the timer reaches 1 minute it will start to flash.
After the correct stabilisation period has elapsed press
the
Scroll/Enter Key
The
Start Pressure
will be stored and displayed on the
middle line.
The
Timer
will continue to count up with the
Live Pressure Reading
still being displayed on the top
line.
Once the required test period has elapsed press the
Scroll/Enter Key
The
Stop Pressure
Reading
will be stored and
displayed on the bottom line.
The
Start Pressure Reading
will be displayed on the
middle line and both will be flashing.
The timer will stop with the
Live Pressure Reading
being displayed on the top line.