background image

LOCATION OF HEATER

Heaters should be located to provide a blanket of
heat over the coldest wall of the room, preferably
on a outside wall under a window.

CAUTIONS AND WARNING STATEMENTS

1. Wiring procedures and connections should be

in accordance with national and local codes
having jurisdiction.  Note: all baseboards must
be grounded in accordance with article 250 of
the National Electrical Code.

2. Do not install baseboard heater below electrical

convenience receptacles (outlets).

3. Do not install heaters against combustible low

density cellulose fiberboard surfaces.

4. High temperatures are present at outlet air

openings.  Keep electrical cords, drapes and
other furnishings or objects clear of these
openings.

5. To reduce risk of fire, do not store or use

gasoline or other flammable vapors and liguids
in the vicinity of the heater.

6. Heaters are designed for surface mounting only.

Do not recess the heaters into the wall.

7. Do not tamper with or remove the temperature

limiting device.

RECOMMENDATIONS FOR DRAPE
PLACEMENT NEAR 
BASEBOARD HEATER

1. Allow minimum clearance of 1” from drapes to ceiling

and to top of floor covering to permit air circulation
(Example 1, Figure 1).

2. Hang full length drapes to provide a minimum of 2”

air space between heater front and nearest drape
fold as shown in Example 1, Figure 1.

3. Hang short drapes to provide minimum of 6”

clearance between bottom of drapes and top of
heater, preferably more (Example 2, Figure 1).

4. Do not under any condition allow drapery to come

in contact with heater.  Some fabrics discolor in time
from exposure sunlight or warm air. Check to make
sure drapery material will not discolor, shrink, or
stretch upon extended (1000 hour) exposure to
temperatures of 200

o

F.

Heaters may be mounted directly to any floor
surface, including carpeting.  Wall to wall carpet
(maximum thickness 3/4”) may extend under or to
the front of the baseboard heater.  This is provided
the flooring material does not obstruct air flow to
the heater.

5. Do not install vinyl curtains, drapes or blinds above

the heater as they may discolor or deform.

Commercial / Residential

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION

 INSTRUCTIONS

ATTENTION: Read carefully before attempting to
install, operate or service the Baseboard Heater.
Retain these instructions for future reference.

1

8981 - REV.

3700 SERIES ELECTRIC BASEBOARD HEATER

Summary of Contents for 3900WW108

Page 1: ...s to ceiling and to top of floor covering to permit air circulation Example 1 Figure 1 2 Hang full length drapes to provide a minimum of 2 air space between heater front and nearest drape fold as shown in Example 1 Figure 1 3 Hang short drapes to provide minimum of 6 clearance between bottom of drapes and top of heater preferably more Example 2 Figure 1 4 Do not under any condition allow drapery t...

Page 2: ...for expasion If a stud is not available use the appropriate fastener such as toggle bolts or molly screw anchors for hollow walls or screws and anchors for masonry walls 5 Replace the front cover by snapping it over the element retaining brackets 6 Remove the wire nut in the wiring compartment and connect the power supply as shown in the wiring diagrams Figure 3 If you are using one of the field i...

Page 3: ...FIGURE 1 FIGURE 2 FIGURE 3 ...

Page 4: ... to baseboard with screws provided 5 Mount baseboard to wall refer to baseboard installation instructions 6 Complete wiring connections inside junction boxes for continuous parallel wiring 7 Re install junction box covers and check heater for proper operation INSTRUCTIONS FOR PRE INSTALLED WIREWAY ADAPTER 1 Remove junction box covers 2 Using means to protect the heater finish place baseboard face ...

Page 5: ...p nut connection 3 Make the connections per the wiring diagram Connect the wires marked Line to the supply Connect the wires marked Load to the baseboard Make sure all connections are secure 4 Install transfer switch receptacle cover assembly to baseboard junction box and secure with screw previously removed 5 Restore power and check for proper operation 8924 REV 110206 IMPORTANT OWNER SHOULD RETA...

Page 6: ...tions must conform to the National Electric Code and local codes having jurisdiction NOTES Do not eliminate or bypass the thermal cutout Do not exceed the nameplate rating The inbuilt accessory can be mounted in either end of the baseboard heater 1 Remove the baseboard junction box cover and retain the screw 2 Remove the wire nut in the junction box Do not remove the crimp nut connection 3 Make th...

Page 7: ...hat the wires are at the top of the baseboard 3 Remove wire nut and wire as shown in diagram below 4 Replace covers and restore power to the unit check for proper operation 8926 REV 110206 IMPORTANT OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE SHOWN WIRED LEFT END ELEMENT BLACK BLUE RED LOW VOLTAGE THERMOSTAT WIRE WIRE NUT CONTROL SECTION OVER TEMP LIMIT CONTROL GND LEFT JUNCTION BO...

Page 8: ...in accordance with National Electric Code 1 The receptacle cover assembly can be mounted in the left or right hand junction box 2 Remove the baseboard heater junction box cover and retain the screw 3 Attach the 120V branch supply leads and ground lead to the receptacle Use copper conductors only 4 Install receptacle cover assembly to the baseboard junction box and secure with previously removed sc...

Page 9: ...l Electric Code and local codes having jurisdiction NOTES Do not eliminate or bypass the thermal cutout Do not exceed the nameplate rating The inbuilt accessory can be mounted in either end of the baseboard heater 1 Remove the baseboard junction box cover and retain the screw 2 Remove the wire nut in the junction box Do not remove the crimp nut connection 3 Make the connections per the wiring diag...

Page 10: ... baseboard heaters that are to be joined by the corner section 2 Remove a knockout from the exposed end of one of the baseboard junction boxes and insert the snap bushing provided 3 Remove the front cover of the corner section mount the corner section to the wall 4 Position the baseboard s next to the corner section and feed the corner section ground wire through the bushing 5 Mount and wire the b...

Page 11: ...n the wall adjacent to the baseboard Using the drill guide drill two 3 16 holes in the back of the control section and mount to the wall with the appropriate fasteners Insert the snap bushing in the knockout holes 4 Wire the desired accessory per the installation instructions and replace covers using the end plate of the baseboard for the exposed end of the control section 5 Restore the power and ...

Page 12: ...ity of ground 3 Wire baseboard s as required and install covers 5 Restore power and check for proper operation 8931 REV 110706 IMPORTANT OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE BLANK SECTION ELEMENT OVER TEMP LIMIT CONTROL GND LEFT JUNCTION BOX GND RIGHT JUNCTION BOX LEFT JUNCTION BOX RIGHT JUNCTION BOX CRIMP NUT ELEMENT TEMP LIMITING DEVICE SHOWN WIRED LEFT END GND BLANK SECTI...

Page 13: ...to ceiling and to top of floor covering to permit air circulation Example 1 Figure 1 2 Hang full length drapes to provide a minimum of 2 air space between heater front and nearest drape fold as shown in Example 1 Figure 1 3 Hang short drapes to provide minimum of 6 clearance between bottom of drapes and top of heater preferably more Example 2 Figure 1 4 Do not under any condition allow drapery to ...

Page 14: ...pasion If a stud is not available use the appropriate fastener such as toggle bolts or molly screw anchors for hollow walls or screws and anchors for masonry walls 5 Replace the front cover by snapping it over the element retaining brackets 6 Remove the wire nut in the wiring compartment and connect the power supply as shown in the wiring diagrams Figure 3 If you are using one of the field install...

Page 15: ...URE LIMITING DEVICE 1 43 1 60 WIRE NUT 2 1 ELEMENT TEMP LIMIT DEVICE GND GND CRIMP NUT WIRE NUT ELEMENT TEMP LIMIT DEVICE GND CRIMP NUT ELEMENT TEMP LIMIT DEVICE CRIMP NUT WIRE NUT L1 L2 N GND GND GND MULTIPLE UNIT WIRING WIRING DIAGRAM 8981 REV 3 ...