7. Insert the flexible exhaust pipe to the flexible bent joint

until it locks. Insert the flexible bent joint to the exhaust

mouth of the inner flue pipe until it locks.

8. Insert the extension pipe "A" into the extension pipe "B"

until the tab provided on the end of the former is

engaged with the O-ring in the inside of the latter on

the side which does not have the tab. Next insert the

flexible pipe, which is attached to the unit, into the

extension pipe "A" and then connect the extension pipe

"B" end of the assembly of these pipes to the exhaust

mouth of the Water Heater. And assemble another set

of the pipes in the similar manner.

Note: 1. Slide the insulating cloth cover on the

extension pipe "B", before connecting the

above-mentioned pipe assembly to the Water

Heater.

2. When disconnecting the extension pipe (such

as flexible pipe and flexible elbow), pull the

pipe by turning the pipe clockwise.

9. Remove the screw from the exhaust mouth of the unit.

Insert the flexible exhaust pipe to the exhaust mouth

and secure them with the screw.

NOTE: Seal all connections of the pipes with the

aluminum tape.

Insulating
cloth cover

Nail

Flexible
bent joint

Flexible
exhaust pipe

Nail

Inner flue
pipe

Flexible bent joint

10. Connect rubber joints to both ends of the inlet hose.

11. Pass the hose band for standard flue pipe set, which is

attached to the unit, through one of the rubber joints,

next connect the rubber joint into the air intake mouth

of the flue pipe, and then secure the piping with the

hose band.

12. Next pass the hose band through the other rubber joint

and then secure the extension pipe "A", which has been

connected to the air intake mouth of the Water Heater,

with the hose band.

13. Fix the extension pipes with the pipe support brackets.

After installing the flue pipe, secure the extension pipes

by connecting them with the pipe support brackets.

Adjust the pitch of the pipe fixing brackets for flue pipe

tops as in the following.

If the clearance between the extension pipe "A" and "B",

is too wide, cut the pipe support bracket to the

appropriate size.

Cut

1-1/2 in.(50mm)

Screw

Nut

Self tapping 
screw

Self tapping 
screw

Rubber joint

Rubber joint

Inlet hose

Rubber joint

Hose band

Rubber joint

14. Apply aluminum tape to the joints of the extension

pipes "A" and "B", flexible pipe, and the flexible bent

joint, in order to prevent emissions.

15. After assembling the parts as above, do a trial

operation to the Water Heater and check to see if it

works properly and that there are not any emission

leaks from the joints.

16. Other installation of flue pipe than above-mentioned

can also be made by using the bent joint with the

extension pipe kit, depending on the installing location

of the Water Heater or of the flue pipe.

Rubber joint

Flexible bent  
joint

Flexible 

exhaust pipe

Aluminum 

tape

Insulating cloth 

cover

Water Heater

Inlet hose

Hose band

Extension 

pipe "A"

Pipe fixing
bracket

Screw

Extension 
pipe "B"

NOTE: Remote flue pipe installations are possible by

using of this extension pipe kit.

BE SURE TO FOLLOW THE INSTRUCTIONS
IN THIS MANUAL.

The instructions which are contained in this manual are

classified into the following two types, which are

"WARNING" and "CAUTION". These instructions are

intended to provide the important information for safe

operation.

"WARNING"

indicates the possibility of causing a fatal

accident or serious injury, if handled

incorrectly .

"CAUTION"

indicates the possibility of causing injuries

or material damages, if handled incorrectly.

Instantaneous Kerosene Fired Water Heater

ACCESSORY

INSTRUCTION MANUAL

FOR EXTENSION PIPE KIT SH-70UFF

PART# 20476496

TOYOTOMI U.S.A., INC.

P.O. Box 176, Brookfield, CT 06804-0176

Printed in Japan

2604001501

Rev. 2/99

Summary of Contents for SH-70UFF

Page 1: ...rackets After installing the flue pipe secure the extension pipes by connecting them with the pipe support brackets Adjust the pitch of the pipe fixing brackets for flue pipe tops as in the following...

Page 2: ...ject Exhaust gas Exhaust gas Combustible object 1 Select unit location Allow clearances as indicated above between the unit and all other materials 2 Make sure that the outside area to where the flue...

Page 3: ...ject Exhaust gas Exhaust gas Combustible object 1 Select unit location Allow clearances as indicated above between the unit and all other materials 2 Make sure that the outside area to where the flue...

Page 4: ...ject Exhaust gas Exhaust gas Combustible object 1 Select unit location Allow clearances as indicated above between the unit and all other materials 2 Make sure that the outside area to where the flue...

Page 5: ...ject Exhaust gas Exhaust gas Combustible object 1 Select unit location Allow clearances as indicated above between the unit and all other materials 2 Make sure that the outside area to where the flue...

Page 6: ...rackets After installing the flue pipe secure the extension pipes by connecting them with the pipe support brackets Adjust the pitch of the pipe fixing brackets for flue pipe tops as in the following...

Page 7: ...rackets After installing the flue pipe secure the extension pipes by connecting them with the pipe support brackets Adjust the pitch of the pipe fixing brackets for flue pipe tops as in the following...

Page 8: ...rackets After installing the flue pipe secure the extension pipes by connecting them with the pipe support brackets Adjust the pitch of the pipe fixing brackets for flue pipe tops as in the following...

Reviews: