CHARGING SYSTEM
-
I g n i t ion Main Relay
I H J 6 0, 61
Series 1
I G N I T I O N MAIN R E LA Y
[ H J 6 0 , 6 1
Series]
I N SPECTION O F I G N I T I O N MAIN R E LA Y
CH-25
LOCATION: Under t h e insHument panel o n t h e front
d rive side in the relay box.
1 .
I N SPECT RELAY C O N TI N U IT Y
(a) C heck
t ha t t h e r e is c o n t i n u i t y between terminals
1
and
3 .
(b) Check t h a t there is no continuity between terminals
2
and 4 .
I f continUity is nOI a s specified. replace the re lay.
2.
I N SPECT R E LA Y OPERATION
lal
Apply batt ery voltage acrOSs terminals
1
and
3 .
( b ) C heck that t h ere is c o o l i n u i t y between term i n a l s
2
and 4 .
I f o peration
is 001
a s specified, replace
the
relay.