TOYO INTELLIGENT INVERTER 

EIP66-Z Operating Manual 

 

Summary of Contents for VF66 EIP66-Z

Page 1: ...TOYO INTELLIGENT INVERTER EIP66 Z Operating Manual...

Page 2: ......

Page 3: ...Z properly This manual describes the terminal block functions of EIP66 Z board wiring switch settings and VF66 inverter settings For the EtherNet IP communication functions refer to EIP66 Z Communica...

Page 4: ...esults depending on the situation Cautions described in this manual are all important Be sure to observe them CAUTION Installation Do not use the product if it is found damaged or deformed in unpackin...

Page 5: ...refully before starting operation Otherwise injury failure damage may result CAUTION Operation Do not touch the inverter radiation fin or discharge resistor because it can be very hot Ignoring this ma...

Page 6: ...Others 11 CHAPTER 3 Board Description 12 3 1 Part Names 12 3 2 EIP66 Z Switches 13 3 3 How to Mount 14 3 4 LED 16 CHAPTER 4 Multifunction Input 18 4 1 Multifunction Input 18 CHAPTER 5 Analog Input Out...

Page 7: ...For the EtherNet IP communication functions refer to EIP66 Z Communication Protocol Manual This function can also be used as an input output signal of the internal PLC function of the VF66 inverter F...

Page 8: ...lection 3 is set for the multifunction input terminal 8 Acceleration or deceleration time selection 1 is set for the multifunction input terminal 9 For more information about multifunction input termi...

Page 9: ...al For the analog output 2 terminal the output range can be selected from 0 to 10 V and 0 to 10 V maximum current 1 mA by changing of VF66 inverter setting parameter The setting is made so that the in...

Page 10: ...ASE T IEEE802 3u 100BASE TX Transmission speed 10 100 Mbps automatic switching Communication mode Full duplex half duplex automatic switching Connection type Star daisy chain connection Interface RJ 4...

Page 11: ...before wiring Otherwise electric shock fire may result Be sure to turn off the inverter power before changing the connection of jumper socket Otherwise electric shock injury failure malfunction may r...

Page 12: ...g input signal characteristics changeover switch SW1 Jumper connector for switching multifunction input signal characteristics CN SI CN SO PG input output terminal block TB2 EtherNet IP module status...

Page 13: ...VF66 inverter as well For more information refer to CHAPTER 5 SW2 PG frequency division output switch Changes the output waveform of frequency divided PG signal 1 4 frequency divided signal is output...

Page 14: ...nal board has already been mounted remove it according to the following procedure If another optional board is not mounted proceed to 6 First remove the SET66 Z board to remove an optional board safel...

Page 15: ...ush the board until the pawl part of the support is hooked to the top of the board as shown in Figure 3 5 Fit the EIP66 Z board connectors CN1 and CN2 into the VFC66 Z board connectors CN7 and CN4 res...

Page 16: ...Port1 CN4 respectively LED3 LINK0 and LED4 LINK1 operation Lights up when a link is established in the network LED3 and LED4 support Port0 CN3 and Port1 CN4 respectively LED5 MS operation The module...

Page 17: ...functions normally LED7 blinks at intervals of approx one second If LED7 does not blink normally after power on the following causes are suspected Poor contact between VFC66 Z and EIP66 Z Failure of...

Page 18: ...unction input 6 Multi function input 7 Multi function input 8 Multi function input 9 External power supply 12 24V 3 Sink mode use internal power supply 4 Sink mode use external power supply Figure 4 1...

Page 19: ...lay 86A operation 17 External failure signal 3 protection relay 86A operation 18 External failure signal 4 protection relay 86A operation 19 External failure signal 1 protection relay 86A not operated...

Page 20: ...WARNING Wiring Check that the input power is turned off before wiring Otherwise electric shock fire may result Be sure to turn off the inverter power before changing the connection of jumper socket O...

Page 21: ...on item Default Unit G 03 Analog input 2 characteristics selection 0 0 to 10 V 1 0 to 10 V 2 4 to 20 mA 1 Set the parameter to 0 to use the analog input 2 as a torque command Only the 0 to 10 V input...

Page 22: ...nstructions of VF66 inverter main unit The gain and offset for the analog input 1 are adjusted prior to shipment therefore further adjustment is not necessary in normal cases Inverter setting paramete...

Page 23: ...Z short circuited CAUTION Short circuit of terminals Be sure to turn off the inverter power before short circuiting terminals Otherwise electric shock may result Turn on the power and then press the...

Page 24: ...rent power supply and input 20mA of current to terminal AIN2 This number is displayed Turn ON the SW1 switch while the power of the inverter is turned off Adjust the values of L 05 so that the values...

Page 25: ...se operation As for a speed command a 10 V input indicates the analog input 2 upper limit speed G 04 setting whereas a 10 V input indicates a negative value of the analog input 2 upper limit speed G 0...

Page 26: ...2 lower limit speed G 05 setting whereas a 20 mA input indicates the analog input 2 upper limit speed G 04 setting If a negative value is set for the analog input 2 lower limit speed G 05 it will be...

Page 27: ...igure 5 5 Analog input torque command characteristic 5 4 Analog Output 2 Using the analog output 2 function internal variables such as output voltage or speed of inverter and output of internal PLC fu...

Page 28: ...F66 inverter main unit 2 With internal PLC output selected the output register o00009 value is output at the 5 V 20000 rate by the internal PLC function For more information refer to the VF66 PC Tool...

Page 29: ...fset adjustment Display Description Setting band selection item Default Unit L 09 Analog output 2 gain 50 0 to 150 0 100 L 10 Analog output 2 offset 50 0 to 50 0 0 S 09 Analog output 2 adjustment 1 An...

Page 30: ...value to 0 using the JOG key and confirm it with the SET key b 17 is displayed again Select G 09 using the JOG key and confirm it with the SET key Change the value to 0 using the JOG key and confirm i...

Page 31: ...rter operation mode and PG specifications to use Read also the operating instructions of VF66 inverter main unit PG signal input becomes available with the switch SW3 on the EIP66 Z board turned on SW...

Page 32: ...vector mode Set the setting parameter A 10 shown in the above table to 2 and connect a PG wire to the terminal on the EIP66 Z board terminal block TB2 as shown in the following figure because 1 of A 1...

Page 33: ...frequency divided PG signal is output from A signal of PG input The peak value is approx 10 V and duty ratio is one to one Turning SW2 of EIP66 Z to 3 outputs 1 4 frequency divided PG signal whereas...

Page 34: ...becomes unable to perform communication Figure 7 1 Network connection example EIP66 Z is equipped with two connectors for EtherNet IP Either connector can be used to connect to the network Use a shiel...

Page 35: ...he inverter operation protection status current and voltage In addition reading rewriting of inverter settings and reading of traceback data protection history and monitoring data are available For th...

Page 36: ...Blank Page...

Page 37: ......

Page 38: ...this the operating manual may be changed without a preliminary announcement by specification change of a product etc Please understand that it may differ from the contents of the operating manual encl...