background image

 

Page  - 1  

MOVEMENT SENSOR 180

°

(WALL MOUNTING) 

T 76 252 

 

Technical Manual 

 

Toyama Movement sensors are 

intelligent lighting control energy saving sensitivity detectors. Movement 

sensors use Passive infrared (PIR) sensor to detect the human movement and make corresponding triggering of 

loads, say lights. Usage of SMD components not only ensures reliability but also makes the product highly 

compact for its functionality and features. Wide operating voltage range of the Movement sensors makes it 

operational across countries from North America having 127V supply to European countries with 230V supply 

without any field setting. The device is incorporated with the adjustable inbuilt timer to switch OFF the load when 

there is no human movement. The device is also incorporated with Lux detector. 

 Applications:

  Movement sensors can be installed in 

 Office 

/Hotel 

corridors. 

 Stair 

cases/Passage. 

 Stores, 

Classrooms. 

  Common fresh rooms. 

SPECIFICATIONS: 
 

Supply 

voltage 

   : 

 

110 

250V/AC 

  

Supply frequency 

 

 

:  

50-60 Hz 

Rated 

load 

   : 1200W 

Detection 

angle 

   : 

 

180 

°

 

Detection distance 

 

 

:  

20 feet  

Installation height 

 

 

8-9 feet optimum 

Detection motion speed  

 

0.6 - 1.5m/s 

Time – delay 

 

 

 

Minimum:  30 sec / Maximum:  450 sec 

Lux adjustment level 

 

 

:  

10 – 400 lux 

Power consumption 

 

 

:  

0.45W (Static 0.1W) 

Operating Temperature   

 

0 - 55

°

C

 

Standard color of Movement sensor 

White 

Adjust day/night or 

night mode

Adjust delay time from 

30 seconds min(-) to 

450 seconds max(+)

 

Summary of Contents for T 76 252

Page 1: ...without any field setting The device is incorporated with the adjustable inbuilt timer to switch OFF the load when there is no human movement The device is also incorporated with Lux detector Applications Movement sensors can be installed in Office Hotel corridors Stair cases Passage Stores Classrooms Common fresh rooms SPECIFICATIONS Supply voltage 110 250V AC Supply frequency 50 60 Hz Rated load...

Page 2: ...manufacturers of repute If required connect 2 2uF 440V AC Fan Capacitor across CFL with electronic ballasts to avoid blinking in OFF state Connect upto specified wattage of load only For higher loads suitable rated contactor of reputed make can be used Hindrance moving object should not hide the detection window Avoid installing in Bathrooms Make sure air conditioners central heating etc do not cl...

Page 3: ...minimum is 30 sec and the maximum is 450 sec delay OFF Identifies day and night automatically When the trimmer knob is turned towards SUN Position max it can work at the day and night When turned towards MOON position min the sensor will only at night less than 10LUX ambient light c Wrong Movement Detection Field Orientation o r r e c t mo v e me n t At a distance closer to the sensor even slow mo...

Page 4: ...the bulbs Switch ON the breaker Check and correct the connections Turn the lux level adjuster photo fully clockwise Sensitivity is poor Installation height may be high Incorrect moving orientation Obstruction in front of sensor window Install at recommended height Correct moving orientation Remove the obstruction in front of the window DIMENSIONS 60 00 73 00 ALL DIMENSIONS ARE IN mm ...